skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SPECTROPHOTOMETRIC DETERMINATION OF RUTHENIUM

Journal Article · · Analytical Chemistry (U.S.) Formerly Ind. Eng. Chem., Anal. Ed.
DOI:https://doi.org/10.1021/ac60146a004· OSTI ID:4295034

Conditions for the spectrophotometric determination of ruthenium as perruthenate have been established. Stable solutions of perruthenate are obtained only when the tetroxide is distilled into dilute sodium hydroxide (1M) containing hypochlorite. At higher hydroxide concentrations (6M) perruthenate is reduced rapidly by water to ruthenate even in the presence of hypochlorite. From 200 to 400 gamma of ruthenium can be determined to an accuracy of +2% at the 95% confldence level. An improved procedure for the distillation of ruthenium tetroxide which is particularly rapid and clean uses a slurry of sodium bismuthate in dilute sulfuric acid as the oxidant. (auth)

Research Organization:
Argonne National Lab., Lemont, Ill.
Sponsoring Organization:
USDOE
NSA Number:
NSA-13-008669
OSTI ID:
4295034
Journal Information:
Analytical Chemistry (U.S.) Formerly Ind. Eng. Chem., Anal. Ed., Vol. Vol: 31; Other Information: Orig. Receipt Date: 31-DEC-59
Country of Publication:
Country unknown/Code not available
Language:
English