Title: ACCURATE MICROMETER FOR CORROSION SAMPLES

Abstract

A micrometer that utilizes eddy current techniques is described. The gage is capable of measuring nominal 0.5000-in. aluminum rods to an accuracy of plus or minus 0.00005 in., and is unaffected by residual nonconductive surface filins such as oxides or corrosion products. (auth)

Authors:
Publication Date:
Research Org.:
Du Pont de Nemours (E.I.) & Co. Savannah River Lab., Aiken, S.C.
OSTI Identifier:
4176791
Report Number(s):
DP-488
NSA Number:
NSA-14-021670
DOE Contract Number:  
AT(07-2)-1
Resource Type:
Technical Report
Resource Relation:
Other Information: Orig. Receipt Date: 31-DEC-60
Country of Publication:
United States
Language:
English
Subject:
ENGINEERING AND EQUIPMENT; ALUMINUM; CORROSION; EDDY CURRENTS; ELECTRIC CONDUCTIVITY; MEASURED VALUES; OXIDES; RODS; SURFACES; THICKNESS

Citation Formats

Woodward, W.J. ACCURATE MICROMETER FOR CORROSION SAMPLES. United States: N. p., 1960. Web. doi:10.2172/4176791.
Woodward, W.J. ACCURATE MICROMETER FOR CORROSION SAMPLES. United States. doi:10.2172/4176791.
Woodward, W.J. Wed . "ACCURATE MICROMETER FOR CORROSION SAMPLES". United States. doi:10.2172/4176791. https://www.osti.gov/servlets/purl/4176791.
@article{osti_4176791,
title = {ACCURATE MICROMETER FOR CORROSION SAMPLES},
author = {Woodward, W.J.},
abstractNote = {A micrometer that utilizes eddy current techniques is described. The gage is capable of measuring nominal 0.5000-in. aluminum rods to an accuracy of plus or minus 0.00005 in., and is unaffected by residual nonconductive surface filins such as oxides or corrosion products. (auth)},
doi = {10.2172/4176791},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1960},
month = {6}
}

Technical Report:

Save / Share: