skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Image streak techniques: ISKRA-5 facility X-ray space-time and spectral characteristics recording

Abstract

Presented below are the X-ray image streak techniques used to study the spectral- and spectral-spatial time behavior of the ISKRA-5 facility laser-irradiated target X-ray radiation. For this purpose, we developed several 0.1-10 keV range X-ray slit streak cameras with 3x10{sup {minus}11}-s time resolution. Our X-ray imaging layout made it possible to simultaneously project several target images (in different spectral intervals) to the photocathode and streak them synchroniously. These techniques made it possible to: Study the microsphere target and plasma corona implosion dynamics; investigate the well-adjacent plasma electron temperature behavior; determine the compressed core lifetime; and monitor the state of the external (non-irradiated) target surface. 7 refs., 4 figs.

Authors:
; ; ;  [1]
  1. VNIIEF Russian Federal Nuclear Center, Novgorod (Russian Federation)
Publication Date:
OSTI Identifier:
416221
Resource Type:
Journal Article
Journal Name:
Plasma Physics Reports
Additional Journal Information:
Journal Volume: 20; Journal Issue: 1; Other Information: PBD: 1994; TN: Translated from Fizika Plazmy; 20: No. 1, 101-106(1994)
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION; PLASMA; INTERACTIONS; THERMONUCLEAR REACTOR MATERIALS; LASER FUSION REACTORS; X-RAY SPECTROSCOPY; STREAK CAMERAS; PLASMA DIAGNOSTICS

Citation Formats

Lazarchuk, V.P., Murugov, V.M., Petrov, S.I., and Senik, A.V. Image streak techniques: ISKRA-5 facility X-ray space-time and spectral characteristics recording. United States: N. p., 1994. Web.
Lazarchuk, V.P., Murugov, V.M., Petrov, S.I., & Senik, A.V. Image streak techniques: ISKRA-5 facility X-ray space-time and spectral characteristics recording. United States.
Lazarchuk, V.P., Murugov, V.M., Petrov, S.I., and Senik, A.V. Sat . "Image streak techniques: ISKRA-5 facility X-ray space-time and spectral characteristics recording". United States.
@article{osti_416221,
title = {Image streak techniques: ISKRA-5 facility X-ray space-time and spectral characteristics recording},
author = {Lazarchuk, V.P. and Murugov, V.M. and Petrov, S.I. and Senik, A.V.},
abstractNote = {Presented below are the X-ray image streak techniques used to study the spectral- and spectral-spatial time behavior of the ISKRA-5 facility laser-irradiated target X-ray radiation. For this purpose, we developed several 0.1-10 keV range X-ray slit streak cameras with 3x10{sup {minus}11}-s time resolution. Our X-ray imaging layout made it possible to simultaneously project several target images (in different spectral intervals) to the photocathode and streak them synchroniously. These techniques made it possible to: Study the microsphere target and plasma corona implosion dynamics; investigate the well-adjacent plasma electron temperature behavior; determine the compressed core lifetime; and monitor the state of the external (non-irradiated) target surface. 7 refs., 4 figs.},
doi = {},
journal = {Plasma Physics Reports},
number = 1,
volume = 20,
place = {United States},
year = {1994},
month = {12}
}