DECONTAMINATION OF THE KER RUPTURE EXPERIMENT LOOP. TEST SERIES B-TEST NO. 3, TEST SERIES D-TEST NO. 1
Technical Report
·
OSTI ID:4152602
>The Bettis COD(S-4) decontamination process is compared to a Turco- Wyandotte combination decontamination process. Average specific decontamination factors and average total specific corrosion penetration are used for the comparison. The corrosion of stainless steel was of the same order of magnitude for both processes but carbon steel corrosion was higher by a factor of 10 with the Bettis process. The decontamination factors were higher in all cases with the Turco-Wyandotte combination process. Data are tabulated. (auth)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-14-018701
- OSTI ID:
- 4152602
- Report Number(s):
- HW-62844
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-60
- Country of Publication:
- United States
- Language:
- English
Similar Records
DECONTAMINATION OF THE KER RUPTURE EXPERIMENT LOOP TEST SERIES B--TESTS NO. 1 AND 2
ONCE THROUGH DECONTAMINATION STUDIES--INTERIM REPORT NO. 1
DECONTAMINATION STUDIES FOR HAPO HIGH TEMPERATURE REACTOR RECIRCULATION SYSTEMS. Progress Report, June 1958-June 1959
Technical Report
·
Sun Nov 01 00:00:00 EST 1959
·
OSTI ID:4152602
ONCE THROUGH DECONTAMINATION STUDIES--INTERIM REPORT NO. 1
Technical Report
·
Tue Jan 12 00:00:00 EST 1960
·
OSTI ID:4152602
DECONTAMINATION STUDIES FOR HAPO HIGH TEMPERATURE REACTOR RECIRCULATION SYSTEMS. Progress Report, June 1958-June 1959
Technical Report
·
Wed Jun 10 00:00:00 EDT 1959
·
OSTI ID:4152602