DEVICE FOR INVESTIGATION OF ELECTRON SPIN-LATTICE RELAXATION AT LOW TEMPERATURES WITH FREQUENCY OF 9 BHz (in Russian)
Abstract
An apparatus for investigation of electron spin-lattice relaxation at low temperatures, by a method of pulse inversion by means of sinusoidally modulated pulses of a magnetic field, is described. The technique of inversion of the level population of the spin system is discussed. The device permits the measurement of the relaxation time in the range 1-10/sup -3/ sec with an error not exceeding plus or minus 10%. (trauth)
- Authors:
- Publication Date:
- Research Org.:
- Inst. of Radiophysics and Electronics, Academy of Sciences, Ukrainian, SSR
- OSTI Identifier:
- 4130578
- NSA Number:
- NSA-18-005584
- Resource Type:
- Journal Article
- Journal Name:
- Pribory i Tekhn. Eksperim.
- Additional Journal Information:
- Journal Volume: Vol: No. 5; Other Information: Orig. Receipt Date: 31-DEC-64
- Country of Publication:
- Country unknown/Code not available
- Language:
- Russian
- Subject:
- INSTRUMENTATION; ELECTRONS; FREQUENCY; INSTRUMENTS; LATTICES; LOW TEMPERATURE; MAGNETIC FIELDS; MEASURED VALUES; MODULATION; OSCILLATIONS; PULSES; SPIN
Citation Formats
Shamfarov, Ya L. DEVICE FOR INVESTIGATION OF ELECTRON SPIN-LATTICE RELAXATION AT LOW TEMPERATURES WITH FREQUENCY OF 9 BHz. Country unknown/Code not available: N. p., 1963.
Web.
Shamfarov, Ya L. DEVICE FOR INVESTIGATION OF ELECTRON SPIN-LATTICE RELAXATION AT LOW TEMPERATURES WITH FREQUENCY OF 9 BHz. Country unknown/Code not available.
Shamfarov, Ya L. 1963.
"DEVICE FOR INVESTIGATION OF ELECTRON SPIN-LATTICE RELAXATION AT LOW TEMPERATURES WITH FREQUENCY OF 9 BHz". Country unknown/Code not available.
@article{osti_4130578,
title = {DEVICE FOR INVESTIGATION OF ELECTRON SPIN-LATTICE RELAXATION AT LOW TEMPERATURES WITH FREQUENCY OF 9 BHz},
author = {Shamfarov, Ya L},
abstractNote = {An apparatus for investigation of electron spin-lattice relaxation at low temperatures, by a method of pulse inversion by means of sinusoidally modulated pulses of a magnetic field, is described. The technique of inversion of the level population of the spin system is discussed. The device permits the measurement of the relaxation time in the range 1-10/sup -3/ sec with an error not exceeding plus or minus 10%. (trauth)},
doi = {},
url = {https://www.osti.gov/biblio/4130578},
journal = {Pribory i Tekhn. Eksperim.},
number = ,
volume = Vol: No. 5,
place = {Country unknown/Code not available},
year = {Sun Sep 01 00:00:00 EDT 1963},
month = {Sun Sep 01 00:00:00 EDT 1963}
}