STEAM GENERATOR TEST. 1A Loop, Foster Wheeler Steam Generator. CORE I, SEED 2. Section 2. Test Results T-643701
Abstract
Tests were run on the 1A Foster Wheeler steam generator from July 18 to August 3, 1960, in order to provide operating data. Results obtained from steady- state operation at power levels up to 65 Mw and from transient tests in three increments up to 63 Mw are given for downcomer flow, pressure drop, circulation ratio, boiler heat output, and steam purity. (D.L.C.)
- Publication Date:
- Research Org.:
- Duquesne Light Co., Shippingport, Penna.
- OSTI Identifier:
- 4091877
- Report Number(s):
- DLCS-3550201
- NSA Number:
- NSA-15-020408
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-61
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
- Subject:
- REACTOR TECHNOLOGY; GENERATORS; IMPURITIES; LIQUID FLOW; OPERATION; POWER; POWER PLANTS; PRESSURE; REACTORS; SHIPPINGPORT; STEAM; TESTING; TRANSIENTS; WATER COOLANT; WATER MODERATOR
Citation Formats
. STEAM GENERATOR TEST. 1A Loop, Foster Wheeler Steam Generator. CORE I, SEED 2. Section 2. Test Results T-643701. Country unknown/Code not available: N. p., 1961.
Web.
. STEAM GENERATOR TEST. 1A Loop, Foster Wheeler Steam Generator. CORE I, SEED 2. Section 2. Test Results T-643701. Country unknown/Code not available.
. 1961.
"STEAM GENERATOR TEST. 1A Loop, Foster Wheeler Steam Generator. CORE I, SEED 2. Section 2. Test Results T-643701". Country unknown/Code not available.
@article{osti_4091877,
title = {STEAM GENERATOR TEST. 1A Loop, Foster Wheeler Steam Generator. CORE I, SEED 2. Section 2. Test Results T-643701},
author = {},
abstractNote = {Tests were run on the 1A Foster Wheeler steam generator from July 18 to August 3, 1960, in order to provide operating data. Results obtained from steady- state operation at power levels up to 65 Mw and from transient tests in three increments up to 63 Mw are given for downcomer flow, pressure drop, circulation ratio, boiler heat output, and steam purity. (D.L.C.)},
doi = {},
url = {https://www.osti.gov/biblio/4091877},
journal = {},
number = ,
volume = ,
place = {Country unknown/Code not available},
year = {Tue May 16 00:00:00 EDT 1961},
month = {Tue May 16 00:00:00 EDT 1961}
}
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.