LARGE-AREA PLASTIC SCINTILLATION COUNTER
Abstract
The construction and performance of a large-area plastic scintillation counter (50 x 80 x 2 cm/sup 3/) of especially simple design are described. Pulse- height spectra were measured with a beam of minimum ionizing particles hitting different points of the counter. The results are compared with theory. The percentage of light collection and the pulse height are calculated absolutely. The influence of magnetic fields on the performance was determined experimentally. A hundred of these counters are used in the CERN neutrino experiment to give the triggering signal for the spark chambers. (auth)
- Authors:
- Publication Date:
- Research Org.:
- European Organization for Nuclear Research, Geneva
- OSTI Identifier:
- 4089698
- Report Number(s):
- CERN-64-4
- NSA Number:
- NSA-18-010371
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-64
- Country of Publication:
- Switzerland
- Language:
- English
- Subject:
- INSTRUMENTATION; BEAMS; CHARGED PARTICLES; CIRCUITS; DISTRIBUTION; EFFICIENCY; MAGNETIC FIELDS; NEUTRINOS; PERFORMANCE; PHOSPHORS; PLANNING; POLYMERS; SCINTILLATION COUNTERS; SPARK CHAMBERS; SPECTRA; TESTING; TRIGGERS
Citation Formats
Alleyn, E, Faissner, H, Gerber, H J, Heer, E, and Reinharz, M. LARGE-AREA PLASTIC SCINTILLATION COUNTER. Switzerland: N. p., 1964.
Web.
Alleyn, E, Faissner, H, Gerber, H J, Heer, E, & Reinharz, M. LARGE-AREA PLASTIC SCINTILLATION COUNTER. Switzerland.
Alleyn, E, Faissner, H, Gerber, H J, Heer, E, and Reinharz, M. 1964.
"LARGE-AREA PLASTIC SCINTILLATION COUNTER". Switzerland.
@article{osti_4089698,
title = {LARGE-AREA PLASTIC SCINTILLATION COUNTER},
author = {Alleyn, E and Faissner, H and Gerber, H J and Heer, E and Reinharz, M},
abstractNote = {The construction and performance of a large-area plastic scintillation counter (50 x 80 x 2 cm/sup 3/) of especially simple design are described. Pulse- height spectra were measured with a beam of minimum ionizing particles hitting different points of the counter. The results are compared with theory. The percentage of light collection and the pulse height are calculated absolutely. The influence of magnetic fields on the performance was determined experimentally. A hundred of these counters are used in the CERN neutrino experiment to give the triggering signal for the spark chambers. (auth)},
doi = {},
url = {https://www.osti.gov/biblio/4089698},
journal = {},
number = ,
volume = ,
place = {Switzerland},
year = {Tue Jan 14 00:00:00 EST 1964},
month = {Tue Jan 14 00:00:00 EST 1964}
}
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.