Magnetic field shielding by a superconducting cylindrical tube of finite length
Journal Article
·
· Review of Scientific Instruments
The shielding of the internal volume of a superconducting tube from an external magnetic field aligned parallel to the tube axis is incomplete since the ends of the tube are open. The magnetic field at the center of the tube is reduced from the external field by a factor of 1.13 x 10-/p/h/// sub a/, where p=5/3, for a tube length 2h which is at least as large as the diameter 2a.
- Research Organization:
- Department of Physics and Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-33-029010
- OSTI ID:
- 4073767
- Journal Information:
- Review of Scientific Instruments, Vol. 47, Issue 3; Other Information: Orig. Receipt Date: 30-JUN-76; ISSN 0034-6748
- Publisher:
- American Institute of Physics (AIP)
- Country of Publication:
- United States
- Language:
- English
Similar Records
Superconducting MgB2 tubes for Passive Magnetic Field Shielding for the Electron Ion Collider
Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields
Distribution of shielding currents in a cylindrical superconducting tube
Technical Report
·
Mon Nov 18 00:00:00 EST 2019
·
OSTI ID:4073767
Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields
Journal Article
·
Sat Nov 01 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:4073767
+1 more
Distribution of shielding currents in a cylindrical superconducting tube
Conference
·
Fri Mar 01 00:00:00 EST 1985
· IEEE Trans. Magn.; (United States)
·
OSTI ID:4073767