ACTIVITY BUILD-UP CONTROL BY HIGH pH COOLANT. A LITERATURE SURVEY
Abstract
A survey was made of unclassified literature dealing with the control of activity build-up in pressurized water reactors by high-pH coolants. Survey results indicate that a high-pH coolant is desirable for control of induced radioactivity build-up in pressurized water reactors containing significant amounts of stainless steel and that no significant hazards are introduced by adoption of a high-pH coolant. Lithium hydroxide was found to be the most acceptable agent for coolant pH control. Strong-base-form mixed-bed resin is effective in maintaining both coolant pH and coolant purity. (auth)
- Authors:
- Publication Date:
- Research Org.:
- Alco Products, Inc., Schenectady, NY (United States)
- OSTI Identifier:
- 4072317
- Report Number(s):
- APAE-Memo-280
- NSA Number:
- NSA-15-012525
- DOE Contract Number:
- AT(30-1)-2639
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-61
- Country of Publication:
- United States
- Language:
- English
- Subject:
- REACTOR TECHNOLOGY; ACIDITY; ACTIVATION; BIBLIOGRAPHY; CONTROL; COOLANTS; IMPURITIES; LITHIUM HYDROXIDES; MAINTENANCE; PRESSURE; RADIOACTIVITY; REACTORS; RESINS; SAFETY; STAINLESS STEELS; WATER COOLANT
Citation Formats
Bergen, C R. ACTIVITY BUILD-UP CONTROL BY HIGH pH COOLANT. A LITERATURE SURVEY. United States: N. p., 1961.
Web. doi:10.2172/4072317.
Bergen, C R. ACTIVITY BUILD-UP CONTROL BY HIGH pH COOLANT. A LITERATURE SURVEY. United States. https://doi.org/10.2172/4072317
Bergen, C R. 1961.
"ACTIVITY BUILD-UP CONTROL BY HIGH pH COOLANT. A LITERATURE SURVEY". United States. https://doi.org/10.2172/4072317. https://www.osti.gov/servlets/purl/4072317.
@article{osti_4072317,
title = {ACTIVITY BUILD-UP CONTROL BY HIGH pH COOLANT. A LITERATURE SURVEY},
author = {Bergen, C R},
abstractNote = {A survey was made of unclassified literature dealing with the control of activity build-up in pressurized water reactors by high-pH coolants. Survey results indicate that a high-pH coolant is desirable for control of induced radioactivity build-up in pressurized water reactors containing significant amounts of stainless steel and that no significant hazards are introduced by adoption of a high-pH coolant. Lithium hydroxide was found to be the most acceptable agent for coolant pH control. Strong-base-form mixed-bed resin is effective in maintaining both coolant pH and coolant purity. (auth)},
doi = {10.2172/4072317},
url = {https://www.osti.gov/biblio/4072317},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Jan 23 00:00:00 EST 1961},
month = {Mon Jan 23 00:00:00 EST 1961}
}