Title: Operating experiences of the advanced ceramic tube filter (ACTF) for the Wakamatsu 71 MW PFBC demonstration plant and design improvements for the realization of commercial plants

Conference ·
OSTI ID:357900
; ;  [1]
  1. Asahi Glass Co., Ltd., Tokyo (Japan). Ceramics Div.; and others

The ACTF installed at the 71MWe pressurized fluidized bed combustion (PFBC) demonstration plant at Wakamatsu Power Station of Electric Power Development Co., Ltd. is the first demonstration scale ceramic filter system for high temperature and high pressure application. The ACTF is featured by inside to outside gas flow configuration with enhanced downward flow by a self circulation blowdown system, vertically arranged tubes in three compartments, reverse cleaning system with regenerators and water cooled tube sheets. A extinguishing powder injection system is also provided to protect filter tubes from abnormal boiler operation such as unburned carbon combustion within the filter system. This paper reviews the latest operating experiences of the ACTF at Wakamatsu and design improvements required to realize the ACTF system for the commercial PFBC plants.

OSTI ID:
357900
Report Number(s):
CONF-9705116-; ISBN 0-7918-1557-9; TRN: IM9932%%245
Resource Relation:
Conference: 14. international conference on fluidized bed combustion, Vancouver (Canada), 11-16 May 1997; Other Information: PBD: 1997; Related Information: Is Part Of Proceedings of the 14. international conference on fluidized bed combustion: Volume 2; Preto, F.D.S. [ed.] [Canada Centre for Mineral and Energy Technology, Ottawa, Ontario (Canada). Energy Technology Centre]; PB: 647 p.
Country of Publication:
United States
Language:
English