skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Evaluation of pollutant source strengths and control strategies in an innovative residential high-rise building

Abstract

Describes a study undertaken to assess the indoor air quality in the Clos St-Andre, a 78-unit residential complex in downtown Montreal, through the implementation of a monitoring protocol in three of the building`s suites; and to examine the relationships between mechanical ventilation, material emissions, occupant lifestyle, and indoor air pollutant concentrations. The monitoring protocol consisted of tracer gas, air exchange testing, material emission testing, airtightness testing, and the monitoring of air temperature, relative humidity, carbon dioxide, carbon monoxide, formaldehyde, and total volatile organic carbon in the suites. Trends in pollutant concentrations over time in the post-construction period are noted.

Publication Date:
Research Org.:
SIRICON, Ottawa, Ontario (Canada); Innovation Centre for High-Rise and Multiples (Canada)
OSTI Identifier:
350437
Report Number(s):
MIC-99-01637/XAB
TRN: 91020814
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 1998
Country of Publication:
United States
Language:
English
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; INDOOR AIR POLLUTION; APARTMENT BUILDINGS; BUILDING MATERIALS; VENTILATION SYSTEMS; AIR INFILTRATION; AMBIENT TEMPERATURE; HUMIDITY; CARBON DIOXIDE; CARBON MONOXIDE; FORMALDEHYDE; ORGANIC COMPOUNDS; VOLATILE MATTER

Citation Formats

NONE. Evaluation of pollutant source strengths and control strategies in an innovative residential high-rise building. United States: N. p., 1998. Web.
NONE. Evaluation of pollutant source strengths and control strategies in an innovative residential high-rise building. United States.
NONE. 1998. "Evaluation of pollutant source strengths and control strategies in an innovative residential high-rise building". United States. doi:.
@article{osti_350437,
title = {Evaluation of pollutant source strengths and control strategies in an innovative residential high-rise building},
author = {NONE},
abstractNote = {Describes a study undertaken to assess the indoor air quality in the Clos St-Andre, a 78-unit residential complex in downtown Montreal, through the implementation of a monitoring protocol in three of the building`s suites; and to examine the relationships between mechanical ventilation, material emissions, occupant lifestyle, and indoor air pollutant concentrations. The monitoring protocol consisted of tracer gas, air exchange testing, material emission testing, airtightness testing, and the monitoring of air temperature, relative humidity, carbon dioxide, carbon monoxide, formaldehyde, and total volatile organic carbon in the suites. Trends in pollutant concentrations over time in the post-construction period are noted.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = 1998,
month =
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share:
  • This study was conducted to further research in evaluating materials emissions and the resultant indoor air quality in new and occupied houses. Project objectives were: To characterize the material emissions of common construction and finishing materials; to evaluate the quality of the indoor air of R-2000 houses and conventional houses before and after occupancy; to characterize the degree to which the selection and use of healthy house concepts can improve indoor air quality; and to examine the relationships between construction material emissions, occupant-related emissions, ventilation system performance, and subsequent levels of indoor air quality. Project methodology involved monitoring of housemore » characteristics and indoor air quality together with coincidental materials emissions testing. Materials tested included carpet, vinyl and hardwood flooring, plywood, oriented strand board, cabinet frame and board, oil- and latex-based painted wallboard and trim, and counter tops.« less
  • Significant quantities of volatile organic compounds (VOCs) and hazardous air pollutants are released into the atmosphere during USAF maintenance operations. Painting operations conducted in paint spray booths are major sources of these pollutants. Solvent based epoxy primers and solvent-based polyurethane coatings are typically used by the Air Force for painting aircraft and associated equipment. Solvents used in these paints include methyl ethyl ketone (MEK), toluene, lacquer thinner, and other solvents involved in painting and component cleaning. In this report, carbon paper adsorption/catalytic incineration (CPACI) and fluidized-bed catalytic incineration (FBCI) were evaluated as control technologies to destroy VOC emissions from paintmore » spray booths. Simultaneous testing of pilot-scale units was performed to evaluate the technical performance of both technologies. Results showed that each technology maintained greater than 99 percent Destruction and Removal Efficiencies (DREs). Particulate emissions from both pilot-scale units were less than 0.08 grains/dry standard cubic foot. Emissions of the criteria pollutants--sulfur oxides, nitrogen oxides, and carbon monoxide--were also below general regulatory standards for incinerators. Economic evaluations were based on a compilation of manufacturer-supplied data and energy consuption data gathered during the pilot scale testing. CPACM and FBCI technologies are less expensive than standard VOC control technologies when net present costs for a 15-year equipment life are compared.« less
  • As part of a joint demonstration effort involving HUD, DOE, a local public housing authority and Boston Edison, an evaluation of energy and demand saving retrofits was conducted for a tall, residential, low-income building located in Boston. The thirteen story building underwent window, lighting, and heating system control renovations in December, 1992. The success of these retrofits was determined using monthly and hourly whole-building consumption data along with a calibrated DOE-2.1D energy simulation model. According to the model developed, post-retrofit conditions showed reductions in annual energy consumption of 325 MWh and in peak demand of 100 kW. These savings resultedmore » in an annual energy cost savings of $28,000. Over 90% of energy and cost savings were attributed to the window retrofit. Interaction of the reduction in lighting capacity with the building`s electric resistance heating system reduced the potential for energy and demand savings associated with the lighting retrofit. Results from the hourly simulation model also indicate that night setbacks controlled by the energy management system were not implemented. An additional 32 MWh in energy savings could be obtained by bringing this system on-line, however peak demand would be increased by 40 kW as the morning demand for space heat is increased, with a net loss in cost savings of $2,500.« less
  • This report presents the results of an economic evaluation produced as part of the Innovative Clean Coal Technology project, which demonstrated selective catalytic reduction (SCR) technology for reduction of NO{sub x} emissions from utility boilers burning U.S. high-sulfur coal. The document includes a commercial-scale capital and O&M cost evaluation of SCR technology applied to a new facility, coal-fired boiler utilizing high-sulfur U.S. coal. The base case presented herein determines the total capital requirement, fixed and variable operating costs, and levelized costs for a new 250-MW pulverized coal utility boiler operating with a 60-percent NO{sub x} removal. Sensitivity evaluations are includedmore » to demonstrate the variation in cost due to changes in process variables and assumptions. This report also presents the results of a study completed by SCS to determine the cost and technical feasibility of retrofitting SCR technology to selected coal-fired generating units within the Southern electric system.« less