skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Pre-flight dark forward electrical testing of the Mir Cooperative Solar Array

Book ·
OSTI ID:347787
;  [1];  [2]
  1. NASA Lewis Research Center, Cleveland, OH (United States)
  2. NYMA Setar Inc., Brookpark, OH (United States)

The Mir Cooperative Solar Array (MCSA) was developed jointly by the United States and Russia to provide approximately 6 kW of photovoltaic power to the Russian space station Mir. After final assembly in Russia, the MCSA was shipped to the NASA Kennedy Space Center (KSC) in the summer of 1995 and launched to Mir in November 1995. Program managers were concerned of the potential for MCSA damage during the transatlantic shipment and the associated handling operations. To address this concern, NASA Lewis Research Center (LeRC) developed an innovative dark-forward electrical test program to assess the gross electrical condition of each generator following shipment from Russia. The use of dark test techniques, which allow the array to remain in the stowed configuration, greatly simplifies the checkout of large area solar arrays. MCSA dark electrical testing was successfully performed at KSC in July 1995 following transatlantic shipment. Data from this testing enabled engineers to quantify the effects of potential MCSA physical damage that would degrade on-orbit electrical performance. In this paper, an overview of the principles and heritage of photovoltaic array dark testing is given. The specific MCSA dark test program is also described including the hardware, software, testing procedures and test results. The current-voltage (IV) response of both solar cell circuitry and by-pass diode circuitry was obtained. To guide the development of dark test hardware, software and procedures, a dedicated FORTRAN computer code was developed to predict the dark IV responses of generators with a variety of feasible damage modes. By comparing the actual test data with the predictions, the physical condition of the generator could be inferred. Based on this data analysis, no electrical short-circuits or open-circuits were detected. This suggested the MCSA did not sustain physical damage that affected electrical performance during handling and shipment from Russia to the US. Good agreement between the test data and computational predictions indicated MCSA electrical performance was amenable to accurate analysis and was well understood.

OSTI ID:
347787
Report Number(s):
CONF-970701-; TRN: IM9923%%325
Resource Relation:
Conference: 32. intersociety energy conversion engineering conference, Honolulu, HI (United States), 27 Jul - 2 Aug 1997; Other Information: PBD: [1997]; Related Information: Is Part Of Proceedings of the thirty-second intersociety energy conversion engineering conference. Volume 1: Aerospace power systems and technologies; PB: 787 p.
Country of Publication:
United States
Language:
English