skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Superconducting Super Collider (SSC) collider dipole magnet (CDM) cold test stand integration and performance

Abstract

Integration of the General Dynamics specified CDM cold test stand, including 10k ampere DC power supplies, high and low speed data acquisition systems, cryogenic facility, cryogenic distribution and end cans, coil protection system, vacuum leak test equipment and test stand controller is discussed. This paper addresses the lessons learned from the integration of these various equipment items. A description of system performance is presented. Definition of the hardware and software systems and the interface to the CDM is included.

Authors:
 [1]
  1. General Dynamics Space System Div., Hammond, LA (United States)
Publication Date:
OSTI Identifier:
33446
Report Number(s):
CONF-930926-
Journal ID: IEMGAQ; ISSN 0018-9464; TRN: 95:009194
Resource Type:
Journal Article
Journal Name:
IEEE Transactions on Magnetics
Additional Journal Information:
Journal Volume: 30; Journal Issue: 4Pt2; Conference: 13. international conference on magnet technology, Victoria (Canada), 20-24 Sep 1993; Other Information: PBD: Jul 1994
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; SUPERCONDUCTING SUPER COLLIDER; SUPERCONDUCTING MAGNETS; TEST FACILITIES; PERFORMANCE; EQUIPMENT PROTECTION DEVICES; CRYOGENICS; TEMPERATURE RANGE 0000-0013 K; CONTROL SYSTEMS

Citation Formats

Jones, R.E. Superconducting Super Collider (SSC) collider dipole magnet (CDM) cold test stand integration and performance. United States: N. p., 1994. Web. doi:10.1109/20.305650.
Jones, R.E. Superconducting Super Collider (SSC) collider dipole magnet (CDM) cold test stand integration and performance. United States. doi:10.1109/20.305650.
Jones, R.E. Fri . "Superconducting Super Collider (SSC) collider dipole magnet (CDM) cold test stand integration and performance". United States. doi:10.1109/20.305650.
@article{osti_33446,
title = {Superconducting Super Collider (SSC) collider dipole magnet (CDM) cold test stand integration and performance},
author = {Jones, R.E.},
abstractNote = {Integration of the General Dynamics specified CDM cold test stand, including 10k ampere DC power supplies, high and low speed data acquisition systems, cryogenic facility, cryogenic distribution and end cans, coil protection system, vacuum leak test equipment and test stand controller is discussed. This paper addresses the lessons learned from the integration of these various equipment items. A description of system performance is presented. Definition of the hardware and software systems and the interface to the CDM is included.},
doi = {10.1109/20.305650},
journal = {IEEE Transactions on Magnetics},
number = 4Pt2,
volume = 30,
place = {United States},
year = {1994},
month = {7}
}