skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Tank 241-SX-106 tank characterization plan

Abstract

This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-SX-106.

Authors:
Publication Date:
Research Org.:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
32528
Report Number(s):
WHC-SD-WM-TP-314
ON: DE95008837; TRN: 95:009030
DOE Contract Number:
AC06-87RL10930
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 8 Mar 1995
Country of Publication:
United States
Language:
English
Subject:
05 NUCLEAR FUELS; HANFORD RESERVATION; RADIOACTIVE WASTE MANAGEMENT; RADIOACTIVE WASTES; UNDERGROUND STORAGE; TANKS; REMEDIAL ACTION; MONITORING; VAPORS; SAMPLING; CHEMICAL ANALYSIS; ORGANIC COMPOUNDS; FERROCYANIDES

Citation Formats

Homi, C.S. Tank 241-SX-106 tank characterization plan. United States: N. p., 1995. Web. doi:10.2172/32528.
Homi, C.S. Tank 241-SX-106 tank characterization plan. United States. doi:10.2172/32528.
Homi, C.S. Wed . "Tank 241-SX-106 tank characterization plan". United States. doi:10.2172/32528. https://www.osti.gov/servlets/purl/32528.
@article{osti_32528,
title = {Tank 241-SX-106 tank characterization plan},
author = {Homi, C.S.},
abstractNote = {This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-SX-106.},
doi = {10.2172/32528},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Mar 08 00:00:00 EST 1995},
month = {Wed Mar 08 00:00:00 EST 1995}
}

Technical Report:

Save / Share:
  • This report presents the details of the Hanford waste tank characterization study for tank 241-SX-106. The drivers and objectives of the headspace vapor sampling and analysis were in accordance with procedure that were presented in other reports. The vapor and headspace gas samples were collected and analyzed to determine the potential risks to tank farm workers due to fugitive emissions from the tank.
  • An effort is underway to provide waste inventory estimates that will serve as standard characterization source terms for the various waste management activities. As part of this effort, an evaluation of available information for single-shell tank 241-SX-106 was performed, and a best-basis inventory was established. This work follows the methodology that was established by the standard inventory task.
  • A major function of the Tank Waste Remediation System (TWRS) is to characterize waste in support of waste management and disposal activities at the Hanford Site. Analytical data from sampling and analysis and other available information about a tank are compiled and maintained in a tank characterization report. This report and its appendices serve as the tank characterization report for single-shell tank 241-SX-106. The objectives of this report are (1) to use characterization data in response to technical issues associated with tank 241-SX-106 waste and (2) to provide a standard characterization of this waste in terms of a best-basis inventorymore » estimate. Section 2.0 summarizes the response to technical issues, Section 3.0 shows the best-basis inventory estimate, Section 4.0 makes recommendations about the safety status of the tank and additional sampling needs. The appendices contain supporting data and information. This report supports the requirements of the Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1997), Milestone M-44-15b, change request M-44-97-03 to ''issue characterization deliverables consistent with the Waste Information Requirements Documents developed for 1998.''« less
  • This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-SX-106 (referred to as Tank SX-106). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitativemore » results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 4 were observed above the 5-ppbv reporting cutoff. Three tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 7 organic analytes identified are listed in Table 1 and account for approximately 100% of the total organic components in Tank SX-106. Carbon dioxide (CO{sub 2}) was the only permanent gas detected. Tank SX-106 is on the Ferrocyanide Watch List.« less
  • Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.