skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Development of a local internal magnetic field measurement via dual mode (O-X) correlation reflectometry

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1149293· OSTI ID:295679
; ;  [1]
  1. Electrical Engineering Department, University of California, Los Angeles, California 90095 (United States)

A new method to measure the local magnetic field strength internal to a plasma is described using cross correlation of ordinary (O) and extraordinary (X) mode reflectometer signals originating from the naturally occurring turbulence present in all plasmas. This method relies on determination of the peak cross correlation between O- and X-mode signals, which are then assumed to originate from the same spatial location. Since the density at cutoff is known from the incident O-mode frequency, the magnetic field may be determined from the X-mode frequency. This method is expected to be widely applicable to many magnetic confinement devices, including those with magnetic fields {le}0.2{endash}0.3thinspT, where application of other diagnostics may be difficult. {copyright} {ital 1999 American Institute of Physics.}

OSTI ID:
295679
Report Number(s):
CONF-980605-; ISSN 0034-6748; TRN: 99:001865
Journal Information:
Review of Scientific Instruments, Vol. 70, Issue 1; Conference: 12. topical conference on high-temperature plasma diagnostics, Princeton, NJ (United States), 7-11 Jun 1998; Other Information: PBD: Jan 1999
Country of Publication:
United States
Language:
English