skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: High power local ECH in CHS

Abstract

Electron cyclotron heating (ECH) experiments with 200 kW and 400 kW gyrotrons at the frequency of 53.2 GHz have been performed in Compact Helical System (CHS). Microwave power from both gyrotrons is transmitted with quasi-optical transmission line and highly focused on the mid-plane of CHS. The main purpose of these experiments is to understand the heating and energy transport mechanisms in CHS at the low collisional regime. The combination of the magnetic field, focal position and polarization enables the investigation of the on/off axis local heating effect with fundamental and second harmonic ECH. {copyright} {ital 1996 American Institute of Physics.}

Authors:
; ; ; ; ; ; ; ; ; ; ; ; ;  [1]
  1. National Institute for Fusion Science and School of Mathematical and Physical Science, General University for Advanced Studies, Nagoya, 464-01 (Japan)
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
284128
Report Number(s):
CONF-9505105-
Journal ID: APCPCS; ISSN 0094-243X; TRN: 96:021724
Resource Type:
Journal Article
Resource Relation:
Journal Name: AIP Conference Proceedings; Journal Volume: 355; Journal Issue: 1; Conference: 11. topical conference on radio frequency in plasmas, Palm Springs, CA (United States), 17-19 May 1995; Other Information: PBD: Feb 1996
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION; ECR HEATING; ANTENNAS; GHZ RANGE 01-100; PLASMA CONFINEMENT; HELICAL CONFIGURATION; ELECTRON TEMPERATURE; ELECTRON DENSITY

Citation Formats

Kubo, S., Idei, H., Iwase, M., Ohkubo, K., Minami, T., Yamada, I., Narihara, K., Tanaka, K., Wilgen, J.B., Murakami, M., Rasumussen, D.A., Nishimura, K., Okamura, S., and Matsuoka, K. High power local ECH in CHS. United States: N. p., 1996. Web. doi:10.1063/1.49570.
Kubo, S., Idei, H., Iwase, M., Ohkubo, K., Minami, T., Yamada, I., Narihara, K., Tanaka, K., Wilgen, J.B., Murakami, M., Rasumussen, D.A., Nishimura, K., Okamura, S., & Matsuoka, K. High power local ECH in CHS. United States. doi:10.1063/1.49570.
Kubo, S., Idei, H., Iwase, M., Ohkubo, K., Minami, T., Yamada, I., Narihara, K., Tanaka, K., Wilgen, J.B., Murakami, M., Rasumussen, D.A., Nishimura, K., Okamura, S., and Matsuoka, K. 1996. "High power local ECH in CHS". United States. doi:10.1063/1.49570.
@article{osti_284128,
title = {High power local ECH in CHS},
author = {Kubo, S. and Idei, H. and Iwase, M. and Ohkubo, K. and Minami, T. and Yamada, I. and Narihara, K. and Tanaka, K. and Wilgen, J.B. and Murakami, M. and Rasumussen, D.A. and Nishimura, K. and Okamura, S. and Matsuoka, K.},
abstractNote = {Electron cyclotron heating (ECH) experiments with 200 kW and 400 kW gyrotrons at the frequency of 53.2 GHz have been performed in Compact Helical System (CHS). Microwave power from both gyrotrons is transmitted with quasi-optical transmission line and highly focused on the mid-plane of CHS. The main purpose of these experiments is to understand the heating and energy transport mechanisms in CHS at the low collisional regime. The combination of the magnetic field, focal position and polarization enables the investigation of the on/off axis local heating effect with fundamental and second harmonic ECH. {copyright} {ital 1996 American Institute of Physics.}},
doi = {10.1063/1.49570},
journal = {AIP Conference Proceedings},
number = 1,
volume = 355,
place = {United States},
year = 1996,
month = 2
}
  • A model is presented for predicting the pressure gradient in partially developed subcooled boiling of water for velocities from 15 to 30 m/s and inlet peaked, nonuniform axial flux profiles with channel average flux values of 6 MW/m{sup 2}. The partially and fully developed boiling regions are considered separately, however, the same general modeling technique is used for both. several correlations for the void fraction at onset of significant void are considered, and their effect on the channel pressure drop is evaluated. The effect of nonuniform axial heat flux on the channel pressure drop is also evaluated. The model ismore » compared with pressure drop data from the thermal-hydraulic test loop at Oak Ridge National Laboratory and is found to agree with the data within 24%.« less
  • Operating nuclear fuel to higher discharge burnups reduces not only fuel cycle costs but also the volume of radioactive waste requiring disposal. In pressurized water reactors (PWRs), high local power densities are a prerequisite for achieving a high batch burnup.The range of maximum power densities that can be exploited for in-core fuel management and operational flexibility is restricted by the limiting conditions for operation obtained from analyses of anticipated operational occurrences and hypothetical accidents.Since utilities mainly use available margins for implementing advanced in-core fuel management strategies or for power uprating, a suitable parameter for making a rough comparison of themore » present thermal-hydraulic design status of different PWRs is the maximum local heat flux achieved during actual cycles under steady-state full-power conditions. A comparison between Siemens PWRs and the PWR designs of other vendors shows that the maximum local power densities during steady-state operation are usually higher in Siemens PWRs.The main reasons why higher power densities are permissible can usually be attributed to different core surveillance concepts (instrumentation and control) in conjunction with different control assembly management schemes. Moreover, two representative studies conducted with a new methodology using the three-dimensional neutronics/thermal-hydraulics coupled code PANBOX for core transient analysis present additional margins. Especially in plants using the Siemens core surveillance concept, the new methodology yields significant additional margins for PWRs to be operated with even higher permissible local power densities.The additional departure from nucleate boiling ratio (DNBR) margin gained in the representative studies was 0.38. However, utilization of this additional margin is accompanied by larger void fractions within the upper section of the hot channel during normal operation. Therefore, increasing steady-state maximum power densities has to be done gradually while collecting and evaluating operating experience each time. Depending on the specific circumstances at a plant, the gained margin can be utilized not only for more economical core loading patterns (improved low-leakage loading and/or elimination of burnable absorbers) or power uprating but also, in Siemens PWRs, to eliminate having to readjust the DNBR limitation circuit for one or more cycles.Although the concept presented here is specifically tailored to Siemens PWRs, it is obvious that the application of a three-dimensional neutronics/thermal-hydraulics coupled code could also provide significant benefits for non-Siemens PWRs as well.« less
  • Simultaneous measurements of spectroscopic terahertz emissions from and SiC photoluminescent local temperature T(r) distributions of high transition temperature T{sub c} superconducting Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+δ} rectangular mesa devices were made. A local region with T(r) > T{sub c} known as a hot spot can emerge with current bias changes. When the hot spot position was moved to a mesa end by locally heating the mesa surface with a laser beam, the intensity of the emission increased, but no changes to its frequency or line width were observed. These results suggest that higher power radiation is attainable by adjusting the hot spotmore » position.« less
  • Purpose: To assess the role of endorectal magnetic resonance imaging (MRI) in defining local relapse after radical prostatectomy for prostate cancer to help to reassess the clinical target volume (CTV) for adjuvant postprostatectomy radiotherapy. Methods and Materials: Sixty patients undergoing an endorectal MRI before salvage radiotherapy were selected. Spatial coordinates of the relapses were assessed using two reference points: the inferior border of the pubic symphysis (point 1) and the urethro-vesical anastomosis (point 2). Every lesion on MRI was delineated on the planning computed tomography and center of mass coordinates were plotted in two separate diagrams (along the x, y,more » and z axes) with the urethro-vesical anastomosis as the coordinate origin. An 'ideal' CTV was constructed, centered at a point defined by the mathematical means of each of the three coordinates with dimensions defined as twice 2 standard deviations in each of the three axes. The dosimetric impact of the new CTV definition was evaluated in six adjuvantly treated patients. Results: The ideal CTV center of mass was located at coordinates 0 (x), -5 (y), and -3 (z) mm with SDs of 6 (x), 6 (y), and 9 (z) mm, respectively. The CTV size was 24 (x) x 24 (y) x 36 (z) mm. Significant rectal sparing was observed with the new CTV. Conclusions: A CTV with an approximately cylindrical shape ({approx}4 x 3 cm) centered 5 mm posterior and 3 mm inferior to the urethro-vesical anastomosis was defined. Such CTV may reduce the irradiation of normal nontarget tissue in the pelvis potentially improving treatment tolerance.« less
  • Purpose: To determine local tumor control after CT-guided brachytherapy at various dose levels and the prognostic impact of extensive cytoreduction in colorectal liver metastases. Methods and Materials: Seventy-three patients were treated on a single-center prospective trial that was initially designed to be randomized to three dose levels of 15 Gy, 20 Gy, or 25 Gy per lesion, delivered in a single fraction. However, because there was a high rate of cross-over of subjects from higher to lower dose levels, this study is better understood as a prospective trial with three dose levels. No upper size limit for the metastases wasmore » applied. We assessed time to local progression, progression-free survival, and overall survival. Results: According to safety constraints cross-over was performed. The final assignment was n = 98, n = 68, and n = 33 in the 15-Gy, 20-Gy, and 25-Gy groups, respectively. Median diameter of the largest tumor lesion in each patient was 5 cm (range, 1-13.5 cm). Estimated mean local recurrence-free survival for all lesions was 34 months (median not reached). The group assigned to 15 Gy after cross-over displayed 34 local recurrences out of 98 lesions; 20 Gy, 15 out of 68 lesions; 25 Gy, 1 out of 33 lesions. The difference between the 25-Gy and the 20-Gy or 15-Gy group was significant (p < 0.05). Repeated local tumor ablations were the most prominent factor for increased survival and dominated additional systemic antitumor treatments. Conclusions: Local tumor control after CT-guided brachytherapy of colorectal liver metastases demonstrated a strong dose dependency. The role of extensive minimally invasive tumor ablation in metastatic colorectal cancer needs to be further established.« less