Design analysis supporting 101-SY Riser 3A Spraywand Adapter and Lifting Yoke Design
This document contains the results of stress and radiological analysis performed in support of the Riser 3A Spraywand Adapter and Lifting Yoke.
This document contains the results of stress analysis and component sizing for the 101-SY mitigation pump, Water Decon System. Calculations included are a stress analysis of the High Pressure Manifold, the threaded connection on the Yoke Water Connector and a sizing of an air receiver tank.
Cleveland, K.J. Design analysis supporting 101-SY Water Decon System. United States: N. p., 1995.
Web. doi:10.2172/273676.
Cleveland, K.J. Design analysis supporting 101-SY Water Decon System. United States. doi:10.2172/273676.
Cleveland, K.J. Tue .
"Design analysis supporting 101-SY Water Decon System". United States.
doi:10.2172/273676. https://www.osti.gov/servlets/purl/273676.
@article{osti_273676,
title = {Design analysis supporting 101-SY Water Decon System},
author = {Cleveland, K.J.},
abstractNote = {This document contains the results of stress analysis and component sizing for the 101-SY mitigation pump, Water Decon System. Calculations included are a stress analysis of the High Pressure Manifold, the threaded connection on the Yoke Water Connector and a sizing of an air receiver tank.},
doi = {10.2172/273676},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Sep 05 00:00:00 EDT 1995},
month = {Tue Sep 05 00:00:00 EDT 1995}
}