Title: Applications and benefits of catalytic converter thermal management

Technical Report ·
DOI:https://doi.org/10.2172/266686· OSTI ID:266686

A catalytic converter thermal management system (TMS) using variable-conductance vacuum insulation and phase-change thermal storage can maintain the converter temperature above its operating temperature for many hours, allowing most trips to begin with minimal ``cold-start`` emissions. The latest converter TMS prototype was tested on a Ford Taurus (3.0 liter flex-fuel engine) at Southwest Research Institute. Following a 24-hour soak, the FTP-75 emissions were 0.031, 0.13, and 0.066 g/mile for NMHC, CO, and NOx, respectively. Tests were also run using 85% ethanol (E85), resulting in values of 0.005, 0.124, and 0.044 g/mile, and 0.005 g/mile NMOG. Compared to the baseline FTP levels, these values represent reductions of 84% to 96% for NMHC, NMOG, and CO.

Research Organization:
National Renewable Energy Lab. (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC36-83CH10093
OSTI ID:
266686
Report Number(s):
NREL/TP-473-20306; ON: DE96007939; TRN: AHC29616%%83
Resource Relation:
Other Information: PBD: Jul 1996
Country of Publication:
United States
Language:
English