Dose assessment of an accidental exposure at the IPNS
Abstract
Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose ranged from 550 mrem/min to 2850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenetic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem.
- Authors:
- Publication Date:
- Research Org.:
- Argonne National Lab., IL (United States)
- Sponsoring Org.:
- USDOE, Washington, DC (United States)
- OSTI Identifier:
- 26528
- Report Number(s):
- ANL/ESH/HP-95-01
ON: DE95007706; TRN: 95:008369
- DOE Contract Number:
- W-31109-ENG-38
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: Feb 1995
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 56 BIOLOGY AND MEDICINE, APPLIED STUDIES; RADIATION DOSES; EVALUATION; PERSONNEL; NUCLEAR FACILITIES; RADIATION ACCIDENTS; NEUTRON SOURCES; OCCUPATIONAL EXPOSURE
Citation Formats
Campos Torres, M.M. Dose assessment of an accidental exposure at the IPNS. United States: N. p., 1995.
Web. doi:10.2172/26528.
Campos Torres, M.M. Dose assessment of an accidental exposure at the IPNS. United States. doi:10.2172/26528.
Campos Torres, M.M. Wed .
"Dose assessment of an accidental exposure at the IPNS". United States.
doi:10.2172/26528. https://www.osti.gov/servlets/purl/26528.
@article{osti_26528,
title = {Dose assessment of an accidental exposure at the IPNS},
author = {Campos Torres, M.M.},
abstractNote = {Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose ranged from 550 mrem/min to 2850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenetic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem.},
doi = {10.2172/26528},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Feb 01 00:00:00 EST 1995},
month = {Wed Feb 01 00:00:00 EST 1995}
}
-
Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose rates ranged from 550 mrem/min to 2,850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8.more »
-
Dose-response analysis and quantitative assessment of lung-cancer risk and occupational cadmium exposure
A quantitative assessment was performed of the risk of lung cancer from exposure to cadmium (7440439) in a population of workers at a facility that processed cadmium metals and compounds. The population consisted of all workers who worked in a production area for at least 6 months from 1940 through 1969; the vital status of the workers was updated through 1984. A total of 606 white male workers, contributing 16,898 person years and 162 deaths were analyzed. A statistically significant dose response was evident in nearly all of the Poisson regression models evaluated. A nearly significant excess in mortality frommore » -
Health effects and dose-response assessment for hydrogen chloride following short-term exposure. Final report
A project investigated the development of dose-duration-response information for short-term exposure to hydrogen chloride. The approach is one alternative for providing the risk assessor/risk manager a readily available guide for decision making with respect to short-term exposure to hydrogen chloride. The objectives of the project were to provide a detailed analysis of the health effects associated with short-term exposure to hydrogen chloride and to propose an approach for evaluating the hazard to humans exposed to hydrogen chloride for short periods of time. -
Use of international data sets to evaluate and validate pathway assessment models applicable to exposure and dose reconstruction at DOE facilities. Monthly progress reports and final report, October--December 1994
The objective of Task 7.lD was to (1) establish a collaborative US-USSR effort to improve and validate our methods of forecasting doses and dose commitments from the direct contamination of food sources, and (2) perform experiments and validation studies to improve our ability to predict rapidly and accurately the long-term internal dose from the contamination of agricultural soil. At early times following an accident, the direct contamination of pasture and food stuffs, particularly leafy vegetation and grain, can be of great importance. This situation has been modeled extensively. However, models employed then to predict the deposition, retention and transport ofmore » -
Exposure Scenarios and Unit Dose Factors for the Hanford Immobilized Low Activity Tank Waste Performance Assessment
Exposure scenarios are defined to identify potential pathways and combinations of pathways that could lead to radiation exposure from immobilized tank waste. Appropriate data and models are selected to permit calculation of dose factors for each exposure