Title: Evaluation of System Effectiveness for Unloading at Nuclear Power Plants

Abstract

The electrical consumption schedules and the structure of the installed power of the Unified Power System (EES) of Russia are examined. The operating costs of nuclear power plants compared to combined cycle (steam-gas) plants as a function of the depth of nighttime unloading at different times in the fuel campaign of nuclear power plants are calculated. It is shown that running nuclear power plants with variable loading is economically unfavorable compared to unloading of combined cycle plants; in addition, at the end of a campaign, the unloading of a nuclear power plant is limited and requires deeper unloading of the unit all the way to stoppage, which leads to greater system costs.

Authors:
;  [1]
  1. Russian Academy of Sciences, Saratov Scientific Center (Russian Federation)
Publication Date:
OSTI Identifier:
22756143
Resource Type:
Journal Article
Journal Name:
Power Technology and Engineering (Print)
Additional Journal Information:
Journal Volume: 51; Journal Issue: 6; Other Information: Copyright (c) 2018 Springer Science+Business Media, LLC, part of Springer Nature; http://www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 1570-145X
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; 42 ENGINEERING; COMBINED CYCLES; COMPARATIVE EVALUATIONS; NUCLEAR FUELS; NUCLEAR POWER PLANTS; OPERATING COST; SCHEDULES; UNLOADING

Citation Formats

Aminov, R. Z., E-mail: oepran@inbox.ru, and Garievskii, M. V. Evaluation of System Effectiveness for Unloading at Nuclear Power Plants. United States: N. p., 2018. Web. doi:10.1007/S10749-018-0896-2.
Aminov, R. Z., E-mail: oepran@inbox.ru, & Garievskii, M. V. Evaluation of System Effectiveness for Unloading at Nuclear Power Plants. United States. doi:10.1007/S10749-018-0896-2.
Aminov, R. Z., E-mail: oepran@inbox.ru, and Garievskii, M. V. Thu . "Evaluation of System Effectiveness for Unloading at Nuclear Power Plants". United States. doi:10.1007/S10749-018-0896-2.
@article{osti_22756143,
title = {Evaluation of System Effectiveness for Unloading at Nuclear Power Plants},
author = {Aminov, R. Z., E-mail: oepran@inbox.ru and Garievskii, M. V.},
abstractNote = {The electrical consumption schedules and the structure of the installed power of the Unified Power System (EES) of Russia are examined. The operating costs of nuclear power plants compared to combined cycle (steam-gas) plants as a function of the depth of nighttime unloading at different times in the fuel campaign of nuclear power plants are calculated. It is shown that running nuclear power plants with variable loading is economically unfavorable compared to unloading of combined cycle plants; in addition, at the end of a campaign, the unloading of a nuclear power plant is limited and requires deeper unloading of the unit all the way to stoppage, which leads to greater system costs.},
doi = {10.1007/S10749-018-0896-2},
journal = {Power Technology and Engineering (Print)},
issn = {1570-145X},
number = 6,
volume = 51,
place = {United States},
year = {2018},