Title: SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR)

Abstract

Purpose: DEAR is a radiation therapy technique utilizing synchronized motion of gantry and couch during delivery to optimize dose distribution homogeneity and penumbra for treatment of superficial disease. Dose calculation for DEAR is not yet supported by commercial TPSs. The purpose of this study is to demonstrate the feasibility of using a web-based Monte Carlo (MC) simulation tool (VirtuaLinac) to calculate dose distributions for a DEAR delivery. Methods: MC simulations were run through VirtuaLinac, which is based on the GEANT4 platform. VirtuaLinac utilizes detailed linac head geometry and material models, validated phase space files, and a voxelized phantom. The input was expanded to include an XML file for simulation of varying mechanical axes as a function of MU. A DEAR XML plan was generated and used in the MC simulation and delivered on a TrueBeam in Developer Mode. Radiographic film wrapped on a cylindrical phantom (12.5 cm radius) measured dose at a depth of 1.5 cm and compared to the simulation results. Results: A DEAR plan was simulated using an energy of 6 MeV and a 3×10 cm{sup 2} cut-out in a 15×15 cm{sup 2} applicator for a delivery of a 90° arc. The resulting data were found to providemore » qualitative and quantitative evidence that the simulation platform could be used as the basis for DEAR dose calculations. The resulting unwrapped 2D dose distributions agreed well in the cross-plane direction along the arc, with field sizes of 18.4 and 18.2 cm and penumbrae of 1.9 and 2.0 cm for measurements and simulations, respectively. Conclusion: Preliminary feasibility of a DEAR delivery using a web-based MC simulation platform has been demonstrated. This tool will benefit treatment planning for DEAR as a benchmark for developing other model based algorithms, allowing efficient optimization of trajectories, and quality assurance of plans without the need for extensive measurements.« less

Authors:
;  [1];  [2]
  1. Duke University Medical Center, Durham, NC (United States)
  2. Varian Medical Systems, Palo Alto, CA (United States)
Publication Date:
OSTI Identifier:
22649266
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 43; Journal Issue: 6; Other Information: (c) 2016 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; 61 RADIATION PROTECTION AND DOSIMETRY; COMPUTERIZED SIMULATION; DELIVERY; LINEAR ACCELERATORS; MEV RANGE 01-10; MONTE CARLO METHOD; PHASE SPACE; PLANNING; QUALITY ASSURANCE; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY

Citation Formats

Rodrigues, A, Wu, Q, and Sawkey, D. SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR). United States: N. p., 2016. Web. doi:10.1118/1.4956900.
Rodrigues, A, Wu, Q, & Sawkey, D. SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR). United States. doi:10.1118/1.4956900.
Rodrigues, A, Wu, Q, and Sawkey, D. 2016. "SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR)". United States. doi:10.1118/1.4956900.
@article{osti_22649266,
title = {SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR)},
author = {Rodrigues, A and Wu, Q and Sawkey, D},
abstractNote = {Purpose: DEAR is a radiation therapy technique utilizing synchronized motion of gantry and couch during delivery to optimize dose distribution homogeneity and penumbra for treatment of superficial disease. Dose calculation for DEAR is not yet supported by commercial TPSs. The purpose of this study is to demonstrate the feasibility of using a web-based Monte Carlo (MC) simulation tool (VirtuaLinac) to calculate dose distributions for a DEAR delivery. Methods: MC simulations were run through VirtuaLinac, which is based on the GEANT4 platform. VirtuaLinac utilizes detailed linac head geometry and material models, validated phase space files, and a voxelized phantom. The input was expanded to include an XML file for simulation of varying mechanical axes as a function of MU. A DEAR XML plan was generated and used in the MC simulation and delivered on a TrueBeam in Developer Mode. Radiographic film wrapped on a cylindrical phantom (12.5 cm radius) measured dose at a depth of 1.5 cm and compared to the simulation results. Results: A DEAR plan was simulated using an energy of 6 MeV and a 3×10 cm{sup 2} cut-out in a 15×15 cm{sup 2} applicator for a delivery of a 90° arc. The resulting data were found to provide qualitative and quantitative evidence that the simulation platform could be used as the basis for DEAR dose calculations. The resulting unwrapped 2D dose distributions agreed well in the cross-plane direction along the arc, with field sizes of 18.4 and 18.2 cm and penumbrae of 1.9 and 2.0 cm for measurements and simulations, respectively. Conclusion: Preliminary feasibility of a DEAR delivery using a web-based MC simulation platform has been demonstrated. This tool will benefit treatment planning for DEAR as a benchmark for developing other model based algorithms, allowing efficient optimization of trajectories, and quality assurance of plans without the need for extensive measurements.},
doi = {10.1118/1.4956900},
journal = {Medical Physics},
number = 6,
volume = 43,
place = {United States},
year = 2016,
month = 6
}
  • The gamma-gamma lithodensity logging tool is widely used in oil exploration to measure bulk density, porosity, and lithology. Here, combined weight window and biasing approach has been developed to optimize the specific purpose McLDL code for simulating the spectral response of gamma-gamma lithodensity logging tools. The method is based on the use of photon importance maps which are strongly dependent upon the geometric configuration of the logging tool. A subspace in the formation is taken as an importance region and a one-group importance generator is used in conjunction with the current McLDL code. The splitting of a photon only occursmore » within the important subspace, and direction biasing and the exponential transform are applied to drive photons into that region or the detector. The approach has been tested on a computational benchmark problem and the Atlas Wireline Services` commercial gamma-gamma lithodensity logging tool. Compared to the results from the previous McLDL code, this new approach has eliminated the unacceptably large weight fluctuations and substantially improved the code`s performance in computational accuracy and efficiency by decreasing the relative standard deviation in total detection yield by an order of magnitude and increasing the figure of merit by more than 70 times. Also, the revised McLDL code is more efficient than the general purpose Monte Carlo code MCNP in the simulation of gamma-gamma lithodensity logging tool responses.« less
  • Absorbed photoneutron dose to patients undergoing 18 MV x-ray therapy was studied using Monte Carlo simulations based on the MCNPX code. Two separate transport simulations were conducted, one for the photoneutron contribution and another for neutron capture gamma rays. The phantom model used was of a female patient receiving a four-field pelvic box treatment. Photoneutron doses were determinate to be higher for organs and tissues located inside the treatment field, especially those closest to the patient's skin. The maximum organ equivalent dose per x-ray treatment dose achieved within each treatment port was 719 {mu}Sv/Gy to the rectum (180 deg. field),more » 190 {mu}Sv/Gy to the intestine wall (0 deg. field), 51 {mu}Sv/Gy to the colon wall (90 deg. field), and 45 {mu}Sv/Gy to the skin (270 deg. field). The maximum neutron equivalent dose per x-ray treatment dose received by organs outside the treatment field was 65 {mu}Sv/Gy to the skin in the antero-posterior field. A mean value of 5{+-}2 {mu}Sv/Gy was obtained for organs distant from the treatment field. Distant organ neutron equivalent doses are all of the same order of magnitude and constitute a good estimate of deep organ neutron equivalent doses. Using the risk assessment method of the ICRP-60 report, the greatest likelihood of fatal secondary cancer for a 70 Gy dose is estimated to be 0.02% for the pelvic postero-anterior field, the rectum being the organ representing the maximum contribution of 0.011%.« less
  • Purpose: Microbeam radiation therapy (MRT) is an experimental radiotherapy technique that has shown potent antitumor effects with minimal damage to normal tissue in animal studies. This unique form of radiation is currently only produced in a few large synchrotron accelerator research facilities in the world. To promote widespread translational research on this promising treatment technology we have proposed and are in the initial development stages of a compact MRT system that is based on carbon nanotube field emission x-ray technology. We report on a Monte Carlo based feasibility study of the compact MRT system design. Methods: Monte Carlo calculations weremore » performed using EGSnrc-based codes. The proposed small animal research MRT device design includes carbon nanotube cathodes shaped to match the corresponding MRT collimator apertures, a common reflection anode with filter, and a MRT collimator. Each collimator aperture is sized to deliver a beam width ranging from 30 to 200 {mu}m at 18.6 cm source-to-axis distance. Design parameters studied with Monte Carlo include electron energy, cathode design, anode angle, filtration, and collimator design. Calculations were performed for single and multibeam configurations. Results: Increasing the energy from 100 kVp to 160 kVp increased the photon fluence through the collimator by a factor of 1.7. Both energies produced a largely uniform fluence along the long dimension of the microbeam, with 5% decreases in intensity near the edges. The isocentric dose rate for 160 kVp was calculated to be 700 Gy/min/A in the center of a 3 cm diameter target. Scatter contributions resulting from collimator size were found to produce only small (<7%) changes in the dose rate for field widths greater than 50 {mu}m. Dose vs depth was weakly dependent on filtration material. The peak-to-valley ratio varied from 10 to 100 as the separation between adjacent microbeams varies from 150 to 1000 {mu}m. Conclusions: Monte Carlo simulations demonstrate that the proposed compact MRT system design is capable of delivering a sufficient dose rate and peak-to-valley ratio for small animal MRT studies.« less
  • It recently has been shown experimentally that the focusing provided by a longitudinal nonuniform high magnetic field can significantly improve electron beam dose profiles. This could permit precise targeting of tumors near critical areas and minimize the radiation dose to surrounding healthy tissue. The experimental results together with Monte Carlo simulations suggest that the magnetic confinement of electron radiotherapy beams may provide an alternative to proton or heavy ion radiation therapy in some cases. In the present work, the external magnetic field capability of the Monte Carlo code PENELOPE was utilized by providing a subroutine that modeled the actual fieldmore » produced by the solenoid magnet used in the experimental studies. The magnetic field in our simulation covered the region from the vacuum exit window to the phantom including surrounding air. In a longitudinal nonuniform magnetic field, it is observed that the electron dose can be focused in both the transverse and longitudinal directions. The measured dose profiles of the electron beam are generally reproduced in the Monte Carlo simulations to within a few percent in the region of interest provided that the geometry and the energy of the incident electron beam are accurately known. Comparisons for the photon beam dose profiles with and without the magnetic field are also made. The experimental results are qualitatively reproduced in the simulation. Our simulation shows that the excessive dose at the beam entrance is due to the magnetic field trapping and focusing scattered secondary electrons that were produced in the air by the incident photon beam. The simulations also show that the electron dose profile can be manipulated by the appropriate control of the beam energy together with the strength and displacement of the longitudinal magnetic field.« less
  • The most recent experimental results obtained with laser-plasma accelerators are applied to radiotherapy simulations. The narrow electron beam, produced during the interaction of the laser with the gas jet, has a high charge (0.5 nC) and is quasimonoenergetic (170{+-}20 MeV). The dose deposition is calculated in a water phantom placed at different distances from the diverging electron source. We show that, using magnetic fields to refocus the electron beam inside the water phantom, the transverse penumbra is improved. This electron beam is well suited for delivering a high dose peaked on the propagation axis, a sharp and narrow tranverse penumbramore » combined with a deep penetration.« less