Title: A Novel Method for Achievement of Vascular Closure After Misdeployment of an Angio-Seal™ Device

Abstract

No abstract prepared.

Authors:
;  [1]
  1. Washington University School of Medicine, Department of Vascular and Interventional Radiology, Mallinckrodt Institute of Radiology (United States)
Publication Date:
OSTI Identifier:
22645489
Resource Type:
Journal Article
Resource Relation:
Journal Name: Cardiovascular and Interventional Radiology; Journal Volume: 39; Journal Issue: 8; Other Information: Copyright (c) 2016 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); http://www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; BIOMEDICAL RADIOGRAPHY; BLOOD FLOW; BLOOD VESSELS; VASCULAR DISEASES

Citation Formats

Gunn, Andrew J., E-mail: ajgunnmd@gmail.com, E-mail: gunna@mir.wustl.edu, and Saad, Nael E. A Novel Method for Achievement of Vascular Closure After Misdeployment of an Angio-Seal™ Device. United States: N. p., 2016. Web. doi:10.1007/S00270-016-1326-1.
Gunn, Andrew J., E-mail: ajgunnmd@gmail.com, E-mail: gunna@mir.wustl.edu, & Saad, Nael E. A Novel Method for Achievement of Vascular Closure After Misdeployment of an Angio-Seal™ Device. United States. doi:10.1007/S00270-016-1326-1.
Gunn, Andrew J., E-mail: ajgunnmd@gmail.com, E-mail: gunna@mir.wustl.edu, and Saad, Nael E. 2016. "A Novel Method for Achievement of Vascular Closure After Misdeployment of an Angio-Seal™ Device". United States. doi:10.1007/S00270-016-1326-1.
@article{osti_22645489,
title = {A Novel Method for Achievement of Vascular Closure After Misdeployment of an Angio-Seal™ Device},
author = {Gunn, Andrew J., E-mail: ajgunnmd@gmail.com, E-mail: gunna@mir.wustl.edu and Saad, Nael E.},
abstractNote = {No abstract prepared.},
doi = {10.1007/S00270-016-1326-1},
journal = {Cardiovascular and Interventional Radiology},
number = 8,
volume = 39,
place = {United States},
year = 2016,
month = 8
}
  • A 55-year-old male with peripheral arterial disease underwent angioplasty of the right lower limb arteries via antegrade femoral access. Angio-Seal{sup ®} closure device was used to treat the puncture site, whereby the intravascular sealing anchor accidentally embolized into the malleolar region of the right posterior tibial artery. Successful retrieval of the anchor was accomplished by a SpiderFX embolic protection device. This technique may be a useful approach to retrieve embolized foreign bodies via endovascular access.
  • To prospectively evaluate safety and efficacy of a novel vascular closure device (Glubran 2 Seal) after peripheral angiography in patients with peripheral arterial occlusive disease (PAOD). From December 2010 to June 2011, all consecutive patients with PAOD undergoing peripheral angiography were prospectively enrolled onto the study after percutaneous antegrade or retrograde puncture of the common femoral artery. After angiography, the Glubran 2 Seal device was used to achieve hemostasis. The following data were registered: technical success and manual compression duration, patients' discomfort (scale 0-5), operators' technical difficulty (scale 0-5), and vascular complications. The site of hemostasis was evaluated by clinicalmore » inspection and color-coded Duplex ultrasound performed 1 day and 1 month after the procedure. One hundred seventy-eight patients were enrolled (112 male, mean age 70.8 years) with a total of 206 puncture sites, including 104 (50.5 %) antegrade accesses. The device was successful in 198(96.1 %) of 206 procedures, with 8 cases of manual compression lasting longer than 5 min (maximum 20 min). No major vascular complications were observed, resulting in 100 % procedural success. Minor complications occurred in seven procedures (3.4 %), including two cases of pseudoaneurysms, successfully treated by ultrasound-guided glue injection. The mean {+-} standard deviation score for patients' discomfort was 0.9 {+-} 0.7, whereas the mean score for operators' difficulty was 1.2 {+-} 0.9. In patients with PAOD, the Glubran 2 Seal represents a simple, painless, and efficient vascular closure device, able to achieve hemostasis both in antegrade and retrograde accesses.« less
  • PurposeTo intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal{sup ®} vascular closure device (VCD) and manual compression (MC) in a prospective study design.MethodsPatients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal{sup ®}-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)].more » Results were analyzed in a cross-over design.Results48 patients (29 male, median age 62.5 (32–88) years) were included. An ExoSeal{sup ®}-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0–15) vs. 10 (0–80) and 0 (0–75) vs. 25 (0–90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1–7) vs. 6 (2–10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1–3) vs. 5 (2–10) and 1 (1–2) vs. 2 (1–4), respectively; p < 0.0001].ConclusionIntra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal{sup ®} use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.« less
  • No abstract prepared.
  • We compared the use of manual compression and Angio-Seal and Starclose arterial closure devices to achieve hemostasis following common femoral artery (CFA) punctures in order to evaluate safety and efficacy. A prospective nonrandomized, single-center study was carried out on all patients undergoing CFA punctures over 1 year. Hemostasis was achieved using manual compression in 108 cases, Angio-Seal in 167 cases, and Starclose in 151 cases. Device-failure rates were low and not significantly different in the two groups (manual compression and closure devices; p = 0.8). There were significantly more Starclose (11.9%) patients compared to Angio-Seal (2.4%), with successful initial deploymentmore » subsequently requiring additional manual compression to achieve hemostasis (p < 0.0001). A significant number of very thin patients failed to achieve hemostasis (p = 0.014). Major complications were seen in 2.9% of Angio-Seal, 1.9% of Starclose, and 3.7% of manual compression patients, with no significant difference demonstrated; 4.7% of the major complications were seen in female patients compared to 1.3% in males (p = 0.0415). All three methods showed comparable safety and efficacy. Very thin patients are more likely to have failed hemostasis with the Starclose device, although this did not translate into an increased complication rate. There is a significant increased risk of major puncture-site complications in women with peripheral vascular disease.« less