skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The IR Point of View: Action Cameras for IR Action

Abstract

No abstract prepared.

Authors:
;  [1];  [2]
  1. Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)
  2. Tan Tock Seng Hospital, Department of General Surgery (Singapore)
Publication Date:
OSTI Identifier:
22645243
Resource Type:
Journal Article
Resource Relation:
Journal Name: Cardiovascular and Interventional Radiology; Journal Volume: 40; Journal Issue: 4; Other Information: Copyright (c) 2017 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); http://www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; BIOMEDICAL RADIOGRAPHY; DIAGNOSIS; THERAPY; VASCULAR DISEASES

Citation Formats

Pua, Uei, E-mail: druei@yahoo.com, Kwan, Justin, and Tan, Glenn Wei Leong. The IR Point of View: Action Cameras for IR Action. United States: N. p., 2017. Web. doi:10.1007/S00270-016-1542-8.
Pua, Uei, E-mail: druei@yahoo.com, Kwan, Justin, & Tan, Glenn Wei Leong. The IR Point of View: Action Cameras for IR Action. United States. doi:10.1007/S00270-016-1542-8.
Pua, Uei, E-mail: druei@yahoo.com, Kwan, Justin, and Tan, Glenn Wei Leong. Sat . "The IR Point of View: Action Cameras for IR Action". United States. doi:10.1007/S00270-016-1542-8.
@article{osti_22645243,
title = {The IR Point of View: Action Cameras for IR Action},
author = {Pua, Uei, E-mail: druei@yahoo.com and Kwan, Justin and Tan, Glenn Wei Leong},
abstractNote = {No abstract prepared.},
doi = {10.1007/S00270-016-1542-8},
journal = {Cardiovascular and Interventional Radiology},
number = 4,
volume = 40,
place = {United States},
year = {Sat Apr 15 00:00:00 EDT 2017},
month = {Sat Apr 15 00:00:00 EDT 2017}
}
  • The CO{sub 2}ν{sub 3} asymmetric stretching mode is established as a vibrational chromophore for ultrafast two-dimensional infrared (2D-IR) spectroscopic studies of local structure and dynamics in ionic liquids, which are of interest for carbon capture applications. CO{sub 2} is dissolved in a series of 1-butyl-3-methylimidazolium-based ionic liquids ([C{sub 4}C{sub 1}im][X], where [X]{sup −} is the anion from the series hexafluorophosphate (PF{sub 6}{sup −}), tetrafluoroborate (BF{sub 4}{sup −}), bis-(trifluoromethyl)sulfonylimide (Tf{sub 2}N{sup −}), triflate (TfO{sup −}), trifluoroacetate (TFA{sup −}), dicyanamide (DCA{sup −}), and thiocyanate (SCN{sup −})). In the ionic liquids studied, the ν{sub 3} center frequency is sensitive to the local solvationmore » environment and reports on the timescales for local structural relaxation. Density functional theory calculations predict charge transfer from the anion to the CO{sub 2} and from CO{sub 2} to the cation. The charge transfer drives geometrical distortion of CO{sub 2}, which in turn changes the ν{sub 3} frequency. The observed structural relaxation timescales vary by up to an order of magnitude between ionic liquids. Shoulders in the 2D-IR spectra arise from anharmonic coupling of the ν{sub 2} and ν{sub 3} normal modes of CO{sub 2}. Thermal fluctuations in the ν{sub 2} population stochastically modulate the ν{sub 3} frequency and generate dynamic cross-peaks. These timescales are attributed to the breakup of ion cages that create a well-defined local environment for CO{sub 2}. The results suggest that the picosecond dynamics of CO{sub 2} are gated by local diffusion of anions and cations.« less
  • The authors created two miniature scintillation cameras by coupling identical, thin LSO crystals to position sensitive photomultiplier tubes (PSPMTs). The performance of these cameras was established in both single photon and coincidence imaging modes and in relation to similar gamma cameras equipped with NaI(Tl) crystals. The intrinsic spatial resolution of the LSO cameras was 2.3 mm at 140 keV and 1.2 mm at 511 keV. The coincidence time resolution was 3 ns with an energy resolution of 16.5% at 511 keV. With no sources present, an intrinsic event rate of 300/sec/cm{sup 3} of LSO from {sup 176}Lu was observed. Althoughmore » this background count rate may be a limitation in some applications, LSO PSPMT scintillation cameras offer several important performance advantages over similar NaI(Tl) and BGO cameras that include improved count rate performance, coincidence timing, stopping power relative to NaI, and energy resolution relative to BGO.« less
  • Large-field-of-view scintillation cameras are general purpose, cost effective, imaging devices if one maximizes the use of the crystal with respect to the size of the object under study. This means using parallel-hole collimation for large-organ systems to reduce the number of views necessary to complete a study or to obtain a better appreciation of continuity of structure. A further increase in photon utilization is gained for small-organ imaging with converging collimators, which produce images with superior resolution and sensitivity to that obtained with equivalent parallel-hole collimators. The disadvantages of converging collimators, including decreasing field of view and distortion with depth,more » have been insignificant in light of the advantages gained. Larger detectors with converging collimation result in much higher photon input rates to the scintillation crystal in routine clinical studies than has occurred in the past. This requirement places added burdens on electronic circuitry of the cameras. Count rate processing capabilities of 200,000 counts per second are currently available and are necessary for present generation first-pass cardiovascular studies.« less