Title: SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

Abstract

Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2more » µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.« less

Authors:
 [1]
  1. Marsden Medical Physics Associates, Denville, NJ (United States)
Publication Date:
OSTI Identifier:
22642305
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 43; Journal Issue: 6; Other Information: (c) 2016 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; 61 RADIATION PROTECTION AND DOSIMETRY; ACCURACY; CASTRATION; INTRAVENOUS INJECTION; METASTASES; NEOPLASMS; PATIENTS; PROSTATE; RADIATION DOSES; RADIUM; RADIUM 223; SKELETON

Citation Formats

Jennings, G. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223. United States: N. p., 2016. Web. doi:10.1118/1.4956192.
Jennings, G. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223. United States. doi:10.1118/1.4956192.
Jennings, G. Wed . "SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223". United States. doi:10.1118/1.4956192.
@article{osti_22642305,
title = {SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223},
author = {Jennings, G},
abstractNote = {Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.},
doi = {10.1118/1.4956192},
journal = {Medical Physics},
number = 6,
volume = 43,
place = {United States},
year = {Wed Jun 15 00:00:00 EDT 2016},
month = {Wed Jun 15 00:00:00 EDT 2016}
}