Title: SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?

Abstract

Purpose: In the context of evaluating dosimetric impacts of a variety of uncertainties involved in HDR Tandem-and-Ovoid treatment, to study the correlations between conventional point doses and 3D volumetric doses. Methods: For 5 cervical cancer patients treated with HDR T&O, 150 plans were retrospectively created to study dosimetric impacts of the following uncertainties: (1) inter-fractional applicator displacement between two treatment fractions within a single insertion by applying Fraction#1 plan to Fraction#2 CT; (2) positional dwell error simulated from −5mm to 5mm in 1mm steps; (3) simulated temporal dwell error of 0.05s, 0.1s, 0.5s, and 1s. The original plans were based on point dose prescription, from which the volume covered by the prescription dose was generated as the pseudo target volume to study the 3D target dose effect. OARs were contoured. The point and volumetric dose errors were calculated by taking the differences between original and simulated plans. The correlations between the point and volumetric dose errors were analyzed. Results: For the most clinically relevant positional dwell uncertainty of 1mm, temporal uncertainty of 0.05s, and inter-fractional applicator displacement within the same insertion, the mean target D90 and V100 deviation were within 1%. Among these uncertainties, the applicator displacement showed the largestmore » potential target coverage impact (2.6% on D90) as well as the OAR dose impact (2.5% and 3.4% on bladder D2cc and rectum D2cc). The Spearman correlation analysis shows a correlation coefficient of 0.43 with a p-value of 0.11 between target D90 coverage and H point dose. Conclusion: With the most clinically relevant positional and temporal dwell uncertainties and patient interfractional applicator displacement within the same insertion, the dose error is within clinical acceptable range. The lack of correlation between H point and 3D volumetric dose errors is a motivator for the use of 3D treatment planning in cervical HDR brachytherapy.« less

Authors:
;  [1];  [2]; ; ; ; ;  [3]
  1. University of Florida Health Proton Therapy Institute, Jacksonville, FL (United States)
  2. University of Nebraska Medical Center, Omaha, NE (United States)
  3. University of Arkansas for Medical Sciences, Little Rock, AR (United States)
Publication Date:
OSTI Identifier:
22642264
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 43; Journal Issue: 6; Other Information: (c) 2016 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; 61 RADIATION PROTECTION AND DOSIMETRY; BLADDER; BRACHYTHERAPY; COMPUTERIZED TOMOGRAPHY; CORRELATIONS; DOSIMETRY; ERRORS; NEOPLASMS; PATIENTS; RADIATION DOSES; RECTUM; SIMULATION

Citation Formats

Liang, X, Li, Z, Zheng, D, Zhang, X, Narayanasamy, G, Morrill, S, Penagaricano, J, and Paudel, N. SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?. United States: N. p., 2016. Web. doi:10.1118/1.4956148.
Liang, X, Li, Z, Zheng, D, Zhang, X, Narayanasamy, G, Morrill, S, Penagaricano, J, & Paudel, N. SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?. United States. doi:10.1118/1.4956148.
Liang, X, Li, Z, Zheng, D, Zhang, X, Narayanasamy, G, Morrill, S, Penagaricano, J, and Paudel, N. Wed . "SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?". United States. doi:10.1118/1.4956148.
@article{osti_22642264,
title = {SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?},
author = {Liang, X and Li, Z and Zheng, D and Zhang, X and Narayanasamy, G and Morrill, S and Penagaricano, J and Paudel, N},
abstractNote = {Purpose: In the context of evaluating dosimetric impacts of a variety of uncertainties involved in HDR Tandem-and-Ovoid treatment, to study the correlations between conventional point doses and 3D volumetric doses. Methods: For 5 cervical cancer patients treated with HDR T&O, 150 plans were retrospectively created to study dosimetric impacts of the following uncertainties: (1) inter-fractional applicator displacement between two treatment fractions within a single insertion by applying Fraction#1 plan to Fraction#2 CT; (2) positional dwell error simulated from −5mm to 5mm in 1mm steps; (3) simulated temporal dwell error of 0.05s, 0.1s, 0.5s, and 1s. The original plans were based on point dose prescription, from which the volume covered by the prescription dose was generated as the pseudo target volume to study the 3D target dose effect. OARs were contoured. The point and volumetric dose errors were calculated by taking the differences between original and simulated plans. The correlations between the point and volumetric dose errors were analyzed. Results: For the most clinically relevant positional dwell uncertainty of 1mm, temporal uncertainty of 0.05s, and inter-fractional applicator displacement within the same insertion, the mean target D90 and V100 deviation were within 1%. Among these uncertainties, the applicator displacement showed the largest potential target coverage impact (2.6% on D90) as well as the OAR dose impact (2.5% and 3.4% on bladder D2cc and rectum D2cc). The Spearman correlation analysis shows a correlation coefficient of 0.43 with a p-value of 0.11 between target D90 coverage and H point dose. Conclusion: With the most clinically relevant positional and temporal dwell uncertainties and patient interfractional applicator displacement within the same insertion, the dose error is within clinical acceptable range. The lack of correlation between H point and 3D volumetric dose errors is a motivator for the use of 3D treatment planning in cervical HDR brachytherapy.},
doi = {10.1118/1.4956148},
journal = {Medical Physics},
number = 6,
volume = 43,
place = {United States},
year = {Wed Jun 15 00:00:00 EDT 2016},
month = {Wed Jun 15 00:00:00 EDT 2016}
}