Title: SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images

Abstract

Purpose: For African-American patients receiving breast radiotherapy with a bolus, skin darkening can affect the surface visualization when using optical imaging for daily positioning and gating at deep-inspiration breath holds (DIBH). Our goal is to identify a region-of-interest (ROI) that is robust against deteriorating surface image quality due to skin darkening. Methods: We study four patients whose post-mastectomy surfaces are imaged daily with AlignRT (VisionRT, UK) for DIBH radiotherapy and whose surface image quality is degraded toward the end of treatment. To simulate the effects of skin darkening, surfaces from the first ten fractions of each patient are systematically degraded by 25–35%, 40–50% and 65–75% of the total area of the clinically used ROI-ipsilateral-chestwall. The degraded surfaces are registered to the reference surface in six degrees-of-freedom. To identify a robust ROI, three additional reference ROIs — ROI-chest+abdomen, ROI-bilateral-chest and ROI-extended-ipsilateral-chestwall are created and registered to the degraded surfaces. Differences in registration using these ROIs are compared to that using ROI-ipsilateral-chestwall. Results: For three patients, the deviations in the registrations to ROI-ipsilateral-chestwall are > 2.0, 3.1 and 7.9mm on average for 25–35%, 40–50% and 65–75% degraded surfaces, respectively. Rotational deviations reach 11.1° in pitch. For the last patient, registration is consistentmore » to within 2.6mm even on the 65–75% degraded surfaces, possibly because the surface topography has more distinct features. For ROI-bilateral-chest and ROI-extended-ipsilateral-chest registrations deviate in a similar pattern. However, registration on ROI-chest+abdomen is robust to deteriorating image qualities to within 4.2mm for all four patients. Conclusion: Registration deviations using ROI-ipsilateral-chestwall can reach 9.8mm on the 40–50% degraded surfaces. Caution is required when using AlignRT for patients experiencing skin darkening since the accuracy of AlignRT registration deteriorates. To avoid this inaccuracy, we recommend use of ROI-chest+abdomen, on which registration is consistent within 4.2mm even for highly degraded surfaces.« less

Authors:
; ; ; ;  [1]
  1. The Department of Radiation and Cellular Oncology, The University of Chicago Medicine, Chicago, IL (United States)
Publication Date:
OSTI Identifier:
22632154
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 43; Journal Issue: 6; Other Information: (c) 2016 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; 61 RADIATION PROTECTION AND DOSIMETRY; ACCURACY; BIOMEDICAL RADIOGRAPHY; CHEST; IMAGES; MAMMARY GLANDS; PATIENTS; RADIOTHERAPY; SKIN

Citation Formats

Kang, H, Malin, M, Chmura, S, Hasan, Y, and Al-Hallaq, H. SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images. United States: N. p., 2016. Web. doi:10.1118/1.4955927.
Kang, H, Malin, M, Chmura, S, Hasan, Y, & Al-Hallaq, H. SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images. United States. doi:10.1118/1.4955927.
Kang, H, Malin, M, Chmura, S, Hasan, Y, and Al-Hallaq, H. 2016. "SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images". United States. doi:10.1118/1.4955927.
@article{osti_22632154,
title = {SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images},
author = {Kang, H and Malin, M and Chmura, S and Hasan, Y and Al-Hallaq, H},
abstractNote = {Purpose: For African-American patients receiving breast radiotherapy with a bolus, skin darkening can affect the surface visualization when using optical imaging for daily positioning and gating at deep-inspiration breath holds (DIBH). Our goal is to identify a region-of-interest (ROI) that is robust against deteriorating surface image quality due to skin darkening. Methods: We study four patients whose post-mastectomy surfaces are imaged daily with AlignRT (VisionRT, UK) for DIBH radiotherapy and whose surface image quality is degraded toward the end of treatment. To simulate the effects of skin darkening, surfaces from the first ten fractions of each patient are systematically degraded by 25–35%, 40–50% and 65–75% of the total area of the clinically used ROI-ipsilateral-chestwall. The degraded surfaces are registered to the reference surface in six degrees-of-freedom. To identify a robust ROI, three additional reference ROIs — ROI-chest+abdomen, ROI-bilateral-chest and ROI-extended-ipsilateral-chestwall are created and registered to the degraded surfaces. Differences in registration using these ROIs are compared to that using ROI-ipsilateral-chestwall. Results: For three patients, the deviations in the registrations to ROI-ipsilateral-chestwall are > 2.0, 3.1 and 7.9mm on average for 25–35%, 40–50% and 65–75% degraded surfaces, respectively. Rotational deviations reach 11.1° in pitch. For the last patient, registration is consistent to within 2.6mm even on the 65–75% degraded surfaces, possibly because the surface topography has more distinct features. For ROI-bilateral-chest and ROI-extended-ipsilateral-chest registrations deviate in a similar pattern. However, registration on ROI-chest+abdomen is robust to deteriorating image qualities to within 4.2mm for all four patients. Conclusion: Registration deviations using ROI-ipsilateral-chestwall can reach 9.8mm on the 40–50% degraded surfaces. Caution is required when using AlignRT for patients experiencing skin darkening since the accuracy of AlignRT registration deteriorates. To avoid this inaccuracy, we recommend use of ROI-chest+abdomen, on which registration is consistent within 4.2mm even for highly degraded surfaces.},
doi = {10.1118/1.4955927},
journal = {Medical Physics},
number = 6,
volume = 43,
place = {United States},
year = 2016,
month = 6
}
  • Organ and target tissue pharmacokinetics for dosimetry are usually obtained from a longitudinal series of planar gamma camera images. The information is reduced to a series of individual time-activity curves, where each curve represents the mean change in radioactivity concentration over time in a user-defined region-of-interest. We present a method for automated extraction of such information which also converts the longitudinal image set into a single parametric {open_quotes}clearance-rate image{close_quotes} over the whole body. Each of the posterior images was first inverted to create a pseudo-anterior image. Each pseudo-anterior image was then registered to the original anterior image using a symmetricmore » phase-only matched filtering (SPOMF) technique. The transformations required to register each of these image sets to each other over time were obtained, again using SPOMF, but applied to a selected set of sub-regions that exhibited a consistent pattern of radioactivity distribution over time. After the original image set has been modified in this way, the extraction of time-activity-curves for regions-of-interest becomes simpler since a single set of contours will apply to all of the images. By fitting each individual pixel value in the modified set of images, to an exponential function over time, the time-sequential images may be represented by a parametric image of radioactivity clearance rate. Application of this methodology to planar images obtained for radioiodine treatment of thyroid cancer yielded valuable diagnostic and therapeutic information. From the parametric {open_quotes}clearance-rate image,{close_quotes} the stomach was clearly identified as a region of rapid radioiodine clearance and the liver demonstrated continued uptake over the image collection period, suggesting continued production of thyroid hormone by the metastases. Individual tumor metastases showed both uptake and clearance over the 4-day image collection period.« less
  • Image registration of {sup 131}I SPECT with CT scans was performed in a patient with metastatic thyroid carcinoma using an external fiduciary band and a three-dimensional surface-fitting algorithm. Areas of metastatic disease taking up {sup 131}I were accurately localized to the liver, lungs and vertebral bodies, providing information that could not be obtained by planar or SPECT images alone. Based on these findings, further invasive diagnostic procedures were not performed, therefore considerably altering management in this patient. This approach to image registration has immediate clinical utility in the registration and interpretation of SPECT studies with corresponding CT or MRI scans.more » 20 refs., 3 figs.« less
  • Purpose: Stereography can provide a visualization of the skin surface for radiation therapy patients. The aim of this study was to verify the registration algorithm in a commercial image analysis software, 3dMDVultus, for the fusion of stereograms and CT images. Methods: CT and stereographic scans were acquired of a head phantom and a deformable phantom. CT images were imported in 3dMDVultus and the surface contours were generated by threshold segmentation. Stereograms were reconstructed in 3dMDVultus. The resulting surfaces were registered with Vultus algorithm and then exported to in-house registration software and compared with four algorithms: rigid, affine, non-rigid iterative closestmore » point (ICP) and b-spline algorithm. RMS (root-mean-square residuals of the surface point distances) error between the registered CT and stereogram surfaces was calculated and analyzed. Results: For the head phantom, the maximum RMS error between registered CT surfaces to stereogram was 6.6 mm for Vultus algorithm, whereas the mean RMS error was 0.7 mm. For the deformable phantom, the maximum RMS error was 16.2 mm for Vultus algorithm, whereas the mean RMS error was 4.4 mm. Non-rigid ICP demonstrated the best registration accuracy, as the mean of RMS errors were both within 1 mm. Conclusion: The accuracy of registration algorithm in 3dMDVultus was verified and exceeded RMS of 2 mm for deformable cases. Non-rigid ICP and b-spline algorithms improve the registration accuracy for both phantoms, especially in deformable one. For those patients whose body habitus deforms during radiation therapy, more advanced nonrigid algorithms need to be used.« less
  • ANSI/IEEE Standard 80 is widely used to determine electrical currents flowing through the human body as the result of touch and step voltages near transmission and distribution facilities. This paper shows, however, that significant inaccuracies can occur when the ANSI/IEEE Standard 80 proposed method to calculate foot resistances is applied in substations covered by a thin layer of crushed rock or similar covering layers. In particular, it is shown that the errors obtained by using the infinite series expression of the foot resistance are consistently larger than those produced by the simplified expression for clean and contaminated surface layers. Thismore » paper also compares its results with those proposed recently in the literature. It is shown that these recent proposed equations may be subject to major errors under certain conditions. Equivalent Thevenin foot resistances are plotted for various scenarios of clean and contaminated surface covering layers.« less