Title: SU-E-T-417: Experimental Verification of Robustness Optimized Intensity Modulated Proton Therapy Plans for Craniospinal Irradiation

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4924778· OSTI ID:22548462
; ; ; ;  [1];  [1]
  1. Proton Therapy Center, UT MD Anderson Cancer Center, Houston, TX (United States)

Purpose: The robustness-optimized intensity modulated proton therapy (RO-IMPT) plans takes into account the setup errors to eliminate the hot/cold spots caused by setup errors at the junction for craniospinal (CSI) irradiation fields. The RO-IMPT requires a large area for the junction of two fields. This work is to verify the treatment planning system calculated dose with introduction of setup errors by two-dimensional (2D) dose measurement. Two fields of total lengths of 45 cm with junctions of 21 cm were measured. Methods: 2D dose distributions in the coronal plane were measured by a commercial 2D ion-chamber-array detector in a cubic solid water phantom. A total spine field consisting of an upper and a lower spine field was measured at the depths of 5.4 and 6.9 cm. The active area for the measurement was 24×24 cm{sup 2}2. The junction and the area outside the junction of the spine fields were measured separately to complete the verification for the total field. Six different amounts of set-up errors along the superior-inferior direction up to 1.4 cm were intentionally applied. The measured dose with and without set-up errors were compared with the calculated dose with and without set-up errors using Gamma-index analysis. 3%/3mm and 2%/2mm dose/distance agreement criteria were used. The point dose at the center of the junction was also compared. Results: For all fields with various introduced setup errors, 100 % of pixels passed the 3%/3mm criteria and on average 96% of pixels passed 2%/2mm criteria. Differences in the measured and calculated doses were within 1.1%. Conclusion: The efficacy of the robustness for the CSI RO-IMPT plans were verified by measurement. The measurement method can be used for patient treatment field specific QA for CSI RO-IMPT plans in our institution in the near future.

OSTI ID:
22548462
Journal Information:
Medical Physics, Vol. 42, Issue 6; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English