 [1]; ;  [1]; ; ;  [2]
  1. Institut de Mecanique des Fluides de Toulouse, 2 Allee du Professeur Camille Soula, 31400 Toulouse (France)
  2. CEA, DEN, Nuclear Technology Department, F-13108 Saint-Paul-lez-Durance (France)

This study was carried out to understand the response of an eddy current type flowmeter in two phase liquid-metal flow. We use the technique of ellipse fit and correlate the fluctuations in the angle of inclination of this ellipse with the void fraction. The effects of physical parameters such as coil excitation frequency and flow velocity have been studied. The results show the possibility of using an eddy current flowmeter as a gas detector for large void fractions. (authors)