skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SU-E-J-206: Adaptive Radiotherapy for Gynecological Malignancies with MRIGuided Cobolt-60 Radiotherapy

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4924292· OSTI ID:22499310
; ; ; ; ; ;  [1]
  1. UCLA School of Medicine, Los Angeles, CA (United States)

Purpose: Even in the IMRT era, bowel toxicity and bone marrow irradiation remain concerns with pelvic irradiation. We examine the potential gain from an adaptive radiotherapy workflow for post-operative gynecological patients treated to pelvic targets including lymph nodes using MRI-guided Co-60 radiation therapy. Methods: An adaptive workflow was developed with the intent of minimizing time overhead of adaptive planning. A pilot study was performed using retrospectively analyzed images from one patient’s treatment. The patient’s treated plan was created using conventional PTV margins. Adaptive treatment was simulated on the patient’s first three fractions. The daily PTV was created by removing non-target tissue, including bone, muscle and bowel, from the initial PTV based on the daily MRI. The number of beams, beam angles, and optimization parameters were kept constant, and the plan was re-optimized. Normal tissue contours were not adjusted for the re-optimization, but were adjusted for evaluation of plan quality. Plan quality was evaluated based on PTV coverage and normal tissue DVH points per treatment protocol. Bowel was contoured as the entire bowel bag per protocol at our institution. Pelvic bone marrow was contoured per RTOG protocol 1203. Results: For the clinically treated plan, the volume of bowel receiving 45 Gy was 380 cc, 53% of the rectum received 30 Gy, 35% of the bladder received 45 Gy, and 28% of the pelvic bone marrow received 40 Gy. For the adaptive plans, the volume of bowel receiving 45 Gy was 175–201 cc, 55–62% of the rectum received 30 Gy, 21– 27% of the bladder received 45 Gy, and 13–17% of the pelvic bone marrow received 40 Gy. Conclusion: Adaptive planning led to a large reduction of bowel and bone marrow dose in this pilot study. Further study of on-line adaptive techniques for the radiotherapy of pelvic lymph nodes is warranted. Dr. Low is a member of the scientific advisory board of ViewRay, Inc.

OSTI ID:
22499310
Journal Information:
Medical Physics, Vol. 42, Issue 6; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Dosimetric Comparison of Bone Marrow-Sparing Intensity-Modulated Radiotherapy Versus Conventional Techniques for Treatment of Cervical Cancer
Journal Article · Fri Aug 01 00:00:00 EDT 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22499310

Highly Efficient Training, Refinement, and Validation of a Knowledge-based Planning Quality-Control System for Radiation Therapy Clinical Trials
Journal Article · Sun Jan 01 00:00:00 EST 2017 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22499310

Feasibility of dose escalation using intensity-modulated radiotherapy in posthysterectomy cervical carcinoma
Journal Article · Tue Mar 15 00:00:00 EST 2005 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22499310