Title: Study on the parameters of the scanning system for the 300 keV electron accelerator

Abstract

This paper describes the method to identify the magnetic coil parameters of the scanning system. This locally designed low energy electron accelerator with the present energy of 140 keV will be upgraded to 300 keV. In this accelerator, scanning system is required to deflect the energetic electron beam across a titanium foil in vertical and horizontal direction. The excitation current of the magnetic coil is determined by the energy of the electron beam. Therefore, the magnetic coil parameters must be identified to ensure the matching of the beam energy and excitation coil current. As the result, the essential parameters of the effective lengths for X-axis and Y-axis have been found as 0.1198 m and 0.1134 m and the required excitation coil currents which is dependenton the electron beam energies have be identified.

Authors:
; ; ; ; ; ; ; ; ; ;  [1]
  1. Malaysian Nuclear Agency, Bangi, 43000 Kajang. Selangor (Malaysia)
Publication Date:
OSTI Identifier:
22494523
Resource Type:
Journal Article
Resource Relation:
Journal Name: AIP Conference Proceedings; Journal Volume: 1704; Journal Issue: 1; Conference: iNuSTEC2015: International muclear science, technology and engineering conference 2015, Negeri Sembilan (Malaysia), 17-19 Aug 2015; Other Information: (c) 2016 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS; ACCELERATORS; CURRENTS; DESIGN; ELECTRON BEAMS; FOILS; KEV RANGE 100-1000; LENGTH; MAGNET COILS; TITANIUM

Citation Formats

Leo, K. W., Chulan, R. M., E-mail: leo@nm.gov.my, Hashim, S. A., Baijan, A. H., Sabri, R. M., Mohtar, M., Glam, H., Lojius, L., Zahidee, M., Azman, A., and Zaid, M.. Study on the parameters of the scanning system for the 300 keV electron accelerator. United States: N. p., 2016. Web. doi:10.1063/1.4940068.
Leo, K. W., Chulan, R. M., E-mail: leo@nm.gov.my, Hashim, S. A., Baijan, A. H., Sabri, R. M., Mohtar, M., Glam, H., Lojius, L., Zahidee, M., Azman, A., & Zaid, M.. Study on the parameters of the scanning system for the 300 keV electron accelerator. United States. doi:10.1063/1.4940068.
Leo, K. W., Chulan, R. M., E-mail: leo@nm.gov.my, Hashim, S. A., Baijan, A. H., Sabri, R. M., Mohtar, M., Glam, H., Lojius, L., Zahidee, M., Azman, A., and Zaid, M.. 2016. "Study on the parameters of the scanning system for the 300 keV electron accelerator". United States. doi:10.1063/1.4940068.
@article{osti_22494523,
title = {Study on the parameters of the scanning system for the 300 keV electron accelerator},
author = {Leo, K. W. and Chulan, R. M., E-mail: leo@nm.gov.my and Hashim, S. A. and Baijan, A. H. and Sabri, R. M. and Mohtar, M. and Glam, H. and Lojius, L. and Zahidee, M. and Azman, A. and Zaid, M.},
abstractNote = {This paper describes the method to identify the magnetic coil parameters of the scanning system. This locally designed low energy electron accelerator with the present energy of 140 keV will be upgraded to 300 keV. In this accelerator, scanning system is required to deflect the energetic electron beam across a titanium foil in vertical and horizontal direction. The excitation current of the magnetic coil is determined by the energy of the electron beam. Therefore, the magnetic coil parameters must be identified to ensure the matching of the beam energy and excitation coil current. As the result, the essential parameters of the effective lengths for X-axis and Y-axis have been found as 0.1198 m and 0.1134 m and the required excitation coil currents which is dependenton the electron beam energies have be identified.},
doi = {10.1063/1.4940068},
journal = {AIP Conference Proceedings},
number = 1,
volume = 1704,
place = {United States},
year = 2016,
month = 1
}
  • Depth doses of the scanning electron beams from the Saturne Therac-20 linear accelerator at nominal energies of 6,9,13,17, and 20 MeV were measured in polystyrene using a thin window parallel plate ionization chamber. Central axis depth dose curves are derived and are analyzed according to the method of Brahme and Svensson. For each of the five electron energies, values are obtained for the most probable energy at the absorber surface Ep,0, the practical range Rp, the 50% range R50, the therapeutic range R85, the electron dose gradients, total collision energy losses, and other radiation parameters, and these are compared tomore » corresponding values for electron beams from a 22 MeV medical microtron and a 20 MeV betatron.« less
  • The Therac 20 6-MeV scanned electron beam may be used for partial or total skin therapy. The maximum field size at 1 m is 30 x 30 cm defined by a set of primary photon collimators in conjunction with secondary trimmers. We have studied electron beam profiles with and without trimmers at the nominal source--skin distance of 1 m versus extended distances of 3--5 m. We find that the trimmers limit the field size and add little to the beam uniformity at extended distances. Beam energy, dose distributions, and output factors at extended distances were measured for single and multiplemore » field arrangements with and without trimmers. Beam parameters were measured after introducing a degrader that lowered the energy to 3.7 MeV.« less
  • The production of high energy (multi-GeV) proton beams by an electron ring accelerator is considered. Both the final energy and intensity of the proton beam depend on the choice of parameters for the electron ring. Possible sets of parameters, consistent with all the known requirements of ring stability, and which optimize the energy and (or) the intensity of the proton beam, are presented.