skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SU-E-J-66: Significant Anatomical and Dosimetric Changes Observed with the Pharyngeal Constrictor During Head and Neck Radiotherapy Elicited From Daily Deformable Image Registration and Dose Accumulation

Abstract

Purpose: To evaluate the anatomical changes and associated dosimetric consequences to the pharyngeal constrictor (PC) that occurs during head and neck radiotherapy (H&N RT). Methods: A cohort of 13 oro-pharyngeal cancer patients, who had daily CBCT’s for localization, was retrospectively studied. On every 5th CBCT, PC was manually delineated by a radiation oncologist. The anterior-posterior PC thickness was measured at the C3 level. Delivered dose to PC was estimated by calculating daily doses on CBCT’s, and accumulating to corresponding planning CT images. For accumulation, a parameter-optimized B- spline-based deformable image registration algorithm (Elastix) was used, in conjunction with an energy-mass mapping dose transfer algorithm. Mean and maximum dose (Dmean, Dmax) to PC was determined and compared with corresponding planned quantities. Results: The mean (±standard deviation) volume increase (ΔV) and thickness increase (Δt) over the course of 35 total fractions were 54±33% (11.9±7.6 cc), and 63±39% (2.9±1.9 mm), respectively. The resultant cumulative mean dose increase from planned dose to PC (ΔDmean) was 1.4±1.3% (0.9±0.8 Gy), while the maximum dose increase (ΔDmax) was 0.0±1.6% (0.0±1.1 Gy). Patients with adaptive replanning (n=6) showed a smaller mean dose increase than those without (n=7); 0.5±0.2% (0.3±0.1 Gy) vs. 2.2±1.4% (1.4±0.9 Gy). There was a statisticallymore » significant (p<0.0001) strong correlation between ΔDmean and Δt (Pearson coefficient r=0.78), and a moderate-to-strong correlation (r=0.52) between ΔDmean and ΔV. Correlation between ΔDmean and weight loss ΔW (r=0.1), as well as ΔV and ΔW (r=0.2) were negligible. Conclusion: Patients were found to undergo considerable anatomical changes to pharyngeal constrictor during H&N RT, resulting in non-negligible dose deviations from intended dose. Results are indicative that pharyngeal constrictor thickness, measured at C3 level, is a good predictor for the dose change to the organ. Daily deformable registration and dose accumulation provide a reliable means to assess important anatomical and dosimetric changes to pharyngeal constrictor occurring during treatment. This work was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.« less

Authors:
; ; ; ; ; ;  [1]
  1. Henry Ford Health System, Detroit, MI (United States)
Publication Date:
OSTI Identifier:
22494086
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 42; Journal Issue: 6; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; ALGORITHMS; COMPUTERIZED TOMOGRAPHY; FINANCING; HEAD; IMAGES; MANUALS; MEDICAL PERSONNEL; NECK; NEOPLASMS; PATIENTS; RADIATION DOSES; RADIOTHERAPY; THICKNESS

Citation Formats

Kumarasiri, A, Siddiqui, F, Liu, C, Kamal, M, Fraser, C, Chetty, I, and Kim, J. SU-E-J-66: Significant Anatomical and Dosimetric Changes Observed with the Pharyngeal Constrictor During Head and Neck Radiotherapy Elicited From Daily Deformable Image Registration and Dose Accumulation. United States: N. p., 2015. Web. doi:10.1118/1.4924153.
Kumarasiri, A, Siddiqui, F, Liu, C, Kamal, M, Fraser, C, Chetty, I, & Kim, J. SU-E-J-66: Significant Anatomical and Dosimetric Changes Observed with the Pharyngeal Constrictor During Head and Neck Radiotherapy Elicited From Daily Deformable Image Registration and Dose Accumulation. United States. doi:10.1118/1.4924153.
Kumarasiri, A, Siddiqui, F, Liu, C, Kamal, M, Fraser, C, Chetty, I, and Kim, J. Mon . "SU-E-J-66: Significant Anatomical and Dosimetric Changes Observed with the Pharyngeal Constrictor During Head and Neck Radiotherapy Elicited From Daily Deformable Image Registration and Dose Accumulation". United States. doi:10.1118/1.4924153.
@article{osti_22494086,
title = {SU-E-J-66: Significant Anatomical and Dosimetric Changes Observed with the Pharyngeal Constrictor During Head and Neck Radiotherapy Elicited From Daily Deformable Image Registration and Dose Accumulation},
author = {Kumarasiri, A and Siddiqui, F and Liu, C and Kamal, M and Fraser, C and Chetty, I and Kim, J},
abstractNote = {Purpose: To evaluate the anatomical changes and associated dosimetric consequences to the pharyngeal constrictor (PC) that occurs during head and neck radiotherapy (H&N RT). Methods: A cohort of 13 oro-pharyngeal cancer patients, who had daily CBCT’s for localization, was retrospectively studied. On every 5th CBCT, PC was manually delineated by a radiation oncologist. The anterior-posterior PC thickness was measured at the C3 level. Delivered dose to PC was estimated by calculating daily doses on CBCT’s, and accumulating to corresponding planning CT images. For accumulation, a parameter-optimized B- spline-based deformable image registration algorithm (Elastix) was used, in conjunction with an energy-mass mapping dose transfer algorithm. Mean and maximum dose (Dmean, Dmax) to PC was determined and compared with corresponding planned quantities. Results: The mean (±standard deviation) volume increase (ΔV) and thickness increase (Δt) over the course of 35 total fractions were 54±33% (11.9±7.6 cc), and 63±39% (2.9±1.9 mm), respectively. The resultant cumulative mean dose increase from planned dose to PC (ΔDmean) was 1.4±1.3% (0.9±0.8 Gy), while the maximum dose increase (ΔDmax) was 0.0±1.6% (0.0±1.1 Gy). Patients with adaptive replanning (n=6) showed a smaller mean dose increase than those without (n=7); 0.5±0.2% (0.3±0.1 Gy) vs. 2.2±1.4% (1.4±0.9 Gy). There was a statistically significant (p<0.0001) strong correlation between ΔDmean and Δt (Pearson coefficient r=0.78), and a moderate-to-strong correlation (r=0.52) between ΔDmean and ΔV. Correlation between ΔDmean and weight loss ΔW (r=0.1), as well as ΔV and ΔW (r=0.2) were negligible. Conclusion: Patients were found to undergo considerable anatomical changes to pharyngeal constrictor during H&N RT, resulting in non-negligible dose deviations from intended dose. Results are indicative that pharyngeal constrictor thickness, measured at C3 level, is a good predictor for the dose change to the organ. Daily deformable registration and dose accumulation provide a reliable means to assess important anatomical and dosimetric changes to pharyngeal constrictor occurring during treatment. This work was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.},
doi = {10.1118/1.4924153},
journal = {Medical Physics},
number = 6,
volume = 42,
place = {United States},
year = {Mon Jun 15 00:00:00 EDT 2015},
month = {Mon Jun 15 00:00:00 EDT 2015}
}