  1. J-PARC Center, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan)

The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H{sup −} ion source has been successfully operated for about 1 yr. By the world brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. Although no internal-RF-antenna failure, except for the once caused by an excess cesium due to a misoperation, occurred in the operation, many antennas failed in pre-conditionings for the first hundred days. The antenna failure rate was drastically decreased by using an antenna with coating thicker than a standard value and the pre-conditioning procedure repeating 15 min 25 kW RF-power operation and impurity-gas evacuation a few times, before the full power (50 kW) operation.

OSTI ID:
22482949
Journal Information:
Review of Scientific Instruments, Vol. 87, Issue 2; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Maintenance and operation procedure, and feedback controls of the J-PARC RF-driven H{sup −} ion source
Journal Article · Wed Apr 08 00:00:00 EDT 2015 · AIP Conference Proceedings · OSTI ID:22482949

Rod-filter-field optimization of the J-PARC RF-driven H{sup −} ion source
Journal Article · Wed Apr 08 00:00:00 EDT 2015 · AIP Conference Proceedings · OSTI ID:22482949

Fine-tuning to minimize emittances of J-PARC RF-driven H{sup −} ion source
Journal Article · Mon Feb 15 00:00:00 EST 2016 · Review of Scientific Instruments · OSTI ID:22482949