Title: A high-overtone bulk acoustic wave resonator-oscillator-based 4.596 GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock

Abstract

This article reports on the design and characterization of a high-overtone bulk acoustic wave resonator (HBAR)-oscillator-based 4.596 GHz frequency source. A 2.298 GHz signal, generated by an oscillator constructed around a thermally controlled two-port aluminum nitride-sapphire HBAR resonator with a Q-factor of 24 000 at 68 °C, is frequency multiplied by 2–4.596 GHz, half of the Cs atom clock frequency. The temperature coefficient of frequency of the HBAR is measured to be −23 ppm/ °C at 2.298 GHz. The measured phase noise of the 4.596 GHz source is −105 dB rad{sup 2}/Hz at 1 kHz offset and −150 dB rad{sup 2}/Hz at 100 kHz offset. The 4.596 GHz output signal is used as a local oscillator in a laboratory-prototype Cs microcell-based coherent population trapping atomic clock. The signal is stabilized onto the atomic transition frequency by tuning finely a voltage-controlled phase shifter implemented in the 2.298 GHz HBAR-oscillator loop, preventing the need for a high-power-consuming direct digital synthesis. The short-term fractional frequency stability of the free-running oscillator is 1.8 × 10{sup −9} at one second integration time. In locked regime, the latter is improved in a preliminary proof-of-concept experiment at the level of 6.6 × 10{sup −11} τ{sup −1/2} up to a fewmore » seconds and found to be limited by the signal-to-noise ratio of the detected CPT resonance.« less

Authors:
; ; ;  [1]
  1. FEMTO-ST, CNRS, UFC, 26 chemin de l’Epitaphe 25030 Besançon Cedex (France)
Publication Date:
OSTI Identifier:
22482610
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 86; Journal Issue: 11; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ALUMINIUM; DESIGN; ELECTRIC POTENTIAL; GHZ RANGE 01-100; KHZ RANGE 01-100; NOISE; OSCILLATORS; PHASE SHIFT; RESONATORS; SAPPHIRE; SIGNALS; SIGNAL-TO-NOISE RATIO; SOUND WAVES; TEMPERATURE COEFFICIENT; TRAPPING; TUNING; VAPORS

Citation Formats

Daugey, Thomas, Friedt, Jean-Michel, Martin, Gilles, and Boudot, Rodolphe. A high-overtone bulk acoustic wave resonator-oscillator-based 4.596 GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock. United States: N. p., 2015. Web. doi:10.1063/1.4935172.
Daugey, Thomas, Friedt, Jean-Michel, Martin, Gilles, & Boudot, Rodolphe. A high-overtone bulk acoustic wave resonator-oscillator-based 4.596 GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock. United States. doi:10.1063/1.4935172.
Daugey, Thomas, Friedt, Jean-Michel, Martin, Gilles, and Boudot, Rodolphe. 2015. "A high-overtone bulk acoustic wave resonator-oscillator-based 4.596 GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock". United States. doi:10.1063/1.4935172.
@article{osti_22482610,
title = {A high-overtone bulk acoustic wave resonator-oscillator-based 4.596 GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock},
author = {Daugey, Thomas and Friedt, Jean-Michel and Martin, Gilles and Boudot, Rodolphe},
abstractNote = {This article reports on the design and characterization of a high-overtone bulk acoustic wave resonator (HBAR)-oscillator-based 4.596 GHz frequency source. A 2.298 GHz signal, generated by an oscillator constructed around a thermally controlled two-port aluminum nitride-sapphire HBAR resonator with a Q-factor of 24 000 at 68 °C, is frequency multiplied by 2–4.596 GHz, half of the Cs atom clock frequency. The temperature coefficient of frequency of the HBAR is measured to be −23 ppm/ °C at 2.298 GHz. The measured phase noise of the 4.596 GHz source is −105 dB rad{sup 2}/Hz at 1 kHz offset and −150 dB rad{sup 2}/Hz at 100 kHz offset. The 4.596 GHz output signal is used as a local oscillator in a laboratory-prototype Cs microcell-based coherent population trapping atomic clock. The signal is stabilized onto the atomic transition frequency by tuning finely a voltage-controlled phase shifter implemented in the 2.298 GHz HBAR-oscillator loop, preventing the need for a high-power-consuming direct digital synthesis. The short-term fractional frequency stability of the free-running oscillator is 1.8 × 10{sup −9} at one second integration time. In locked regime, the latter is improved in a preliminary proof-of-concept experiment at the level of 6.6 × 10{sup −11} τ{sup −1/2} up to a few seconds and found to be limited by the signal-to-noise ratio of the detected CPT resonance.},
doi = {10.1063/1.4935172},
journal = {Review of Scientific Instruments},
number = 11,
volume = 86,
place = {United States},
year = 2015,
month =
}
  • We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin parallel lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D{sub 1} line of {sup 87}Rb with the current modulation at the {sup 87}Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stabilitymore » (Allan deviation) 2x10{sup -11}{tau}{sup -1/2} for observation times 1 s{<=}{tau}{<=}20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin parallel lin CPT resonance clock with environmental impacts minimized.« less
  • We present an evaluation of the long-term frequency instability and environmental sensitivity of a chip-scale atomic clock based on coherent population trapping, particularly as affected by the light-source subassembly. The long-term frequency stability of this type of device can be dramatically improved by judicious choice of operating parameters of the light-source subassembly. We find that the clock frequency is influenced by the laser-injection current, the laser temperature, and the rf modulation index. The sensitivity of the clock frequency to changes in the laser-injection current or the substrate temperature can be significantly reduced through adjustment of the rf modulation index. Thismore » makes the requirements imposed on the laser-temperature stabilization, in order to achieve a given frequency stability, less severe. The clock-frequency instability due to variations in local oscillator power is shown to be reduced through the choice of an appropriate light intensity inside the cell. The importance of these parameters with regard to the long-term stability of such systems is discussed.« less
  • We proposed a scheme to implement coherent population trapping (CPT) atomic clock based on the transient CPT phenomenon. We proved that the transient transmitted laser power in a typical {lambda} system near CPT resonance features as a damping oscillation. Also, the oscillating frequency is exactly equal to the frequency detuning from the atomic hyperfine splitting. Therefore, we can directly measure the frequency detuning and then compensated to the output frequency of microwave oscillator to get the standard frequency. By this method, we can further simplify the structure of CPT atomic clock, and make it easier to be digitized and miniaturized.
  • We present a microwave frequency standard based on coherent population trapping (CPT) in the {sup 87}Rb D{sub 1} line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 degree sign C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPTmore » signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3x10{sup -9}/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in {sup 87}Rb. The relative frequency stability is approximately 2.3x10{sup -12} for an average time of 68 s.« less
  • A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as amore » microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.« less