skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Determination of energy release zones arising due to current losses in the convolution region of the magnetically insulated transmission lines of the ANGARA-5-1 facility

Abstract

Among the factors limiting electromagnetic pulse transmission to the load in high-power electro-physical facilities, current losses in magnetically insulated transmission lines (MITLs) are of significant importance. One of such facilities is ANGARA-5-1—a multimodule facility with an output electric power of up to 6 TW. A fairly complicated configuration of the magnetic field in the convolution region of several MITLs makes it difficult to fix the places of current losses there. In this work, these places were determined by detecting the positions of IR sources in the convolution region of the MITLs of the ANGARA-5-1 facility.

Authors:
; ; ;  [1]
  1. Troitsk Institute for Innovation and Fusion Research (Russian Federation)
Publication Date:
OSTI Identifier:
22472332
Resource Type:
Journal Article
Journal Name:
Plasma Physics Reports
Additional Journal Information:
Journal Volume: 41; Journal Issue: 5; Other Information: Copyright (c) 2015 Pleiades Publishing, Ltd.; Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 1063-780X
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; ANGARA-5 DEVICE; ELECTRIC CURRENTS; ELECTRIC POWER; ELECTROMAGNETIC PULSES; MAGNETIC FIELDS; POWER TRANSMISSION LINES

Citation Formats

Grabovski, E. V., Gribov, A. N., Laukhin, Ya. N., and Shishlov, A. O., E-mail: Shishlov@triniti.ru. Determination of energy release zones arising due to current losses in the convolution region of the magnetically insulated transmission lines of the ANGARA-5-1 facility. United States: N. p., 2015. Web. doi:10.1134/S1063780X15050037.
Grabovski, E. V., Gribov, A. N., Laukhin, Ya. N., & Shishlov, A. O., E-mail: Shishlov@triniti.ru. Determination of energy release zones arising due to current losses in the convolution region of the magnetically insulated transmission lines of the ANGARA-5-1 facility. United States. doi:10.1134/S1063780X15050037.
Grabovski, E. V., Gribov, A. N., Laukhin, Ya. N., and Shishlov, A. O., E-mail: Shishlov@triniti.ru. Fri . "Determination of energy release zones arising due to current losses in the convolution region of the magnetically insulated transmission lines of the ANGARA-5-1 facility". United States. doi:10.1134/S1063780X15050037.
@article{osti_22472332,
title = {Determination of energy release zones arising due to current losses in the convolution region of the magnetically insulated transmission lines of the ANGARA-5-1 facility},
author = {Grabovski, E. V. and Gribov, A. N. and Laukhin, Ya. N. and Shishlov, A. O., E-mail: Shishlov@triniti.ru},
abstractNote = {Among the factors limiting electromagnetic pulse transmission to the load in high-power electro-physical facilities, current losses in magnetically insulated transmission lines (MITLs) are of significant importance. One of such facilities is ANGARA-5-1—a multimodule facility with an output electric power of up to 6 TW. A fairly complicated configuration of the magnetic field in the convolution region of several MITLs makes it difficult to fix the places of current losses there. In this work, these places were determined by detecting the positions of IR sources in the convolution region of the MITLs of the ANGARA-5-1 facility.},
doi = {10.1134/S1063780X15050037},
journal = {Plasma Physics Reports},
issn = {1063-780X},
number = 5,
volume = 41,
place = {United States},
year = {2015},
month = {5}
}