Title: The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

Journal Article · · Cardiovascular and Interventional Radiology
;  [1];  [2]; ;  [1];  [2]
  1. Tel-Aviv University, Diagnostic and Interventional Imaging Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel)
  2. Tel-Aviv University, Vascular Surgery Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel)

PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSeal VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)

OSTI ID:
22469923
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 38, Issue 3; Conference: CIRSE 2015: Cardiovascular and Interventional Radiological Society of Europe congress, Lisbon (Portugal), 26-30 Sep 2015; Other Information: Copyright (c) 2015 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); http://www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English