Liver stereotactic body radiation therapy (SBRT) is a feasible treatment method for the nonoperable, patient with early-stage liver cancer. Treatment planning for the SBRT is very important and has to consider the simulation accuracy, planning time, treatment efficiency effects etc. The modified dynamic conformal arc (MDCA) technique is a 3-dimensional conformal arc planning method, which has been proposed for liver SBRT planning at our center. In this study, we compared the MDCA technique with the RapidArc technique in terms of planning target volume (PTV) coverage and sparing of organs at risk (OARs). The results show that the MDCA technique has comparable plan quality to RapidArc considering PTV coverage, hot spots, heterogeneity index, and effective liver volume. For the 5 PTVs studied among 4 patients, the MDCA plan, when compared with the RapidArc plan, showed 9% more hot spots, more heterogeneity effect, more sparing of OARs, and lower liver effective volume. The monitor unit (MU) number for the MDCA plan is much lower than for the RapidArc plans. The MDCA plan has the advantages of less planning time, no-collision treatment, and a lower MU number.

Authors:
; ; ;
Publication Date:
OSTI Identifier:
22462420
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Dosimetry; Journal Volume: 40; Journal Issue: 1; Other Information: Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; ACCURACY; COMPARATIVE EVALUATIONS; EFFICIENCY; LIVER; NEOPLASMS; PATIENTS; PLANNING; RADIOTHERAPY; SIMULATION; THREE-DIMENSIONAL CALCULATIONS

Citation Formats

Shi, Chengyu, E-mail: shicy1974@yahoo.com, Chen, Yong, Fang, Deborah, and Iannuzzi, Christopher. Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline. United States: N. p., 2015. Web. doi:10.1016/J.MEDDOS.2014.07.002.
Shi, Chengyu, E-mail: shicy1974@yahoo.com, Chen, Yong, Fang, Deborah, & Iannuzzi, Christopher. Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline. United States. doi:10.1016/J.MEDDOS.2014.07.002.
Shi, Chengyu, E-mail: shicy1974@yahoo.com, Chen, Yong, Fang, Deborah, and Iannuzzi, Christopher. Wed . "Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline". United States. doi:10.1016/J.MEDDOS.2014.07.002.
@article{osti_22462420,
title = {Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline},
author = {Shi, Chengyu, E-mail: shicy1974@yahoo.com and Chen, Yong and Fang, Deborah and Iannuzzi, Christopher},
abstractNote = {Liver stereotactic body radiation therapy (SBRT) is a feasible treatment method for the nonoperable, patient with early-stage liver cancer. Treatment planning for the SBRT is very important and has to consider the simulation accuracy, planning time, treatment efficiency effects etc. The modified dynamic conformal arc (MDCA) technique is a 3-dimensional conformal arc planning method, which has been proposed for liver SBRT planning at our center. In this study, we compared the MDCA technique with the RapidArc technique in terms of planning target volume (PTV) coverage and sparing of organs at risk (OARs). The results show that the MDCA technique has comparable plan quality to RapidArc considering PTV coverage, hot spots, heterogeneity index, and effective liver volume. For the 5 PTVs studied among 4 patients, the MDCA plan, when compared with the RapidArc plan, showed 9% more hot spots, more heterogeneity effect, more sparing of OARs, and lower liver effective volume. The monitor unit (MU) number for the MDCA plan is much lower than for the RapidArc plans. The MDCA plan has the advantages of less planning time, no-collision treatment, and a lower MU number.},
doi = {10.1016/J.MEDDOS.2014.07.002},
journal = {Medical Dosimetry},
number = 1,
volume = 40,
place = {United States},
year = {Wed Apr 01 00:00:00 EDT 2015},
month = {Wed Apr 01 00:00:00 EDT 2015}
}