Title: Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach

Abstract

Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices formore » calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly assumed, but is more superiorly located at T12-L1 for SAT and at L3-L4 for VAT. Furthermore, the optimal anatomic locations for SAT and VAT estimation are not the same, contrary to common assumption. The proposed standardized space mapping achieves high consistency of anatomic localization by accurately managing nonlinearities in the relationships among landmarks. Multiple slices achieve greater improvement in correlation for VAT than for SAT. The optimal locations in the case of multiple slices are not contiguous.« less

Authors:
;  [1];  [2]
  1. Department of Radiology, Medical Image Processing Group, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6021 (United States)
  2. Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6021 (United States)
Publication Date:
OSTI Identifier:
22412507
Resource Type:
Journal Article
Resource Relation:
Journal Name: Medical Physics; Journal Volume: 41; Journal Issue: 6; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; 60 APPLIED LIFE SCIENCES; ABDOMEN; ADIPOSE TISSUE; COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING; OPTIMIZATION

Citation Formats

Tong, Yubing, Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu, and Torigian, Drew A. Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach. United States: N. p., 2014. Web. doi:10.1118/1.4876275.
Tong, Yubing, Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu, & Torigian, Drew A. Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach. United States. doi:10.1118/1.4876275.
Tong, Yubing, Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu, and Torigian, Drew A. 2014. "Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach". United States. doi:10.1118/1.4876275.
@article{osti_22412507,
title = {Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach},
author = {Tong, Yubing and Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu and Torigian, Drew A.},
abstractNote = {Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices for calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly assumed, but is more superiorly located at T12-L1 for SAT and at L3-L4 for VAT. Furthermore, the optimal anatomic locations for SAT and VAT estimation are not the same, contrary to common assumption. The proposed standardized space mapping achieves high consistency of anatomic localization by accurately managing nonlinearities in the relationships among landmarks. Multiple slices achieve greater improvement in correlation for VAT than for SAT. The optimal locations in the case of multiple slices are not contiguous.},
doi = {10.1118/1.4876275},
journal = {Medical Physics},
number = 6,
volume = 41,
place = {United States},
year = 2014,
month = 6
}
  • Purpose: To develop a reliable method to estimate electron density based on anatomic magnetic resonance imaging (MRI) of the brain. Methods and Materials: We proposed a unifying multi-atlas approach for electron density estimation based on standard T1- and T2-weighted MRI. First, a composite atlas was constructed through a voxelwise matching process using multiple atlases, with the goal of mitigating effects of inherent anatomic variations between patients. Next we computed for each voxel 2 kinds of conditional probabilities: (1) electron density given its image intensity on T1- and T2-weighted MR images; and (2) electron density given its spatial location in a referencemore » anatomy, obtained by deformable image registration. These were combined into a unifying posterior probability density function using the Bayesian formalism, which provided the optimal estimates for electron density. We evaluated the method on 10 patients using leave-one-patient-out cross-validation. Receiver operating characteristic analyses for detecting different tissue types were performed. Results: The proposed method significantly reduced the errors in electron density estimation, with a mean absolute Hounsfield unit error of 119, compared with 140 and 144 (P<.0001) using conventional T1-weighted intensity and geometry-based approaches, respectively. For detection of bony anatomy, the proposed method achieved an 89% area under the curve, 86% sensitivity, 88% specificity, and 90% accuracy, which improved upon intensity and geometry-based approaches (area under the curve: 79% and 80%, respectively). Conclusion: The proposed multi-atlas approach provides robust electron density estimation and bone detection based on anatomic MRI. If validated on a larger population, our work could enable the use of MRI as a primary modality for radiation treatment planning.« less
  • Purpose: To validate a model-based segmentation (MBS) algorithm in a commercial radiation treatment planning system for use in propagating the contours of normal anatomic regions of interest (ROIs) through the respiratory phases that constitute a four-dimensional (4D) computed tomography (CT) image data set. Methods and Materials: The 4D CT data sets for 12 patients treated for non-small-cell lung cancer were acquired. Five ROIs were selected for delineation: right and left lungs, spinal cord, heart, and esophagus. These ROIs were manually delineated on the CT data set corresponding to the end-inspiration respiratory phase (0%). An MBS algorithm implemented on the treatmentmore » planning system propagated the ROIs sequentially through the respiratory phases that constituted the 4D CT data sets, concluding with the 0% phase data set, which was propagated from the 90% phase data set. The propagated ROIs on the 0% phase were compared with the original ROIs on that phase by using visual assessment and a quantitative measure of coincidence. Results: Acceptable propagation accuracy within 1 mm of uncertainty was achieved for lungs and spinal cord. Propagation of the heart produced slightly larger contours that were similar to interphysician variations in contouring the heart. The esophagus was poorly propagated because of lack of tissue contrast and definitive shape. Conclusions: The MBS propagation is a promising tool for efficiently propagating contours through the different phases of respiration. However, propagating the esophagus through this technique may be difficult because of the lack of definitive shape and clearer boundaries from surrounding tissue.« less
  • Purpose: While Tube current modulation has been well accepted for CT dose reduction, kV adjusting in clinical settings is still at its early stage. This is mainly due to the limited kV options of most current CT scanners. kV adjusting can potentially reduce radiation dose and optimize image quality. This study is to optimize CT abdomen imaging acquisition based on the assumption of a continuous kV, with the goal to provide the best contrast to noise ratio (CNR). Methods: For a given dose (CTDIvol) level, the CNRs at different kV and pitches were measured with an ACR GAMMEX phantom. Themore » phantom was scanned in a Siemens Sensation 64 scanner and a GE VCT 64 scanner. A constrained mathematical optimization was used to find the kV which led to the highest CNR for the anatomy and pitch setting. Parametric equations were obtained from polynomial fitting of plots of kVs vs CNRs. A suitable constraint region for optimization was chosen. Subsequent optimization yielded a peak CNR at a particular kV for different collimations and pitch setting. Results: The constrained mathematical optimization approach yields kV of 114.83 and 113.46, with CNRs of 1.27 and 1.11 at the pitch of 1.2 and 1.4, respectively, for the Siemens Sensation 64 scanner with the collimation of 32 x 0.625mm. An optimized kV of 134.25 and 1.51 CNR is obtained for a GE VCT 64 slice scanner with a collimation of 32 x 0.625mm and a pitch of 0.969. At 0.516 pitch and 32 x 0.625 mm an optimized kV of 133.75 and a CNR of 1.14 was found for the GE VCT 64 slice scanner. Conclusion: CNR in CT image acquisition can be further optimized with a continuous kV option instead of current discrete or fixed kV settings. A continuous kV option is a key for individualized CT protocols.« less
  • A wide variety of focal and diffuse infectious processes involve the abdomen. At one extreme are diseases such as pyelonephritis, cystitis, and pelvic inflammatory disease, conditions usually diagnosed without imaging studies and treated without complications. At the other extreme are abdominal abscesses, which may defy clinical diagnosis, are associated with significant morbidity and mortality, and may remain undetected or insufficiently characterized in spite of multiple imaging studies. The limited diagnostic value of clinical evaluation and plain film radiography in abscess detection has lead to widespread use of sophisticated imaging techniques including Gallium-67 (67Ga) scintigraphy, Indium-111 WBC (111In-WBC) scintigraphy, computed tomographymore » (CT), and ultrasonography (US). Abdominal abscesses occur in a wide variety of anatomic sites, may involve any abdominal organ system, and have a number of different causes. The heterogeneity of the disease process and the varying capabilities of the different imaging techniques (with respect to site and organ system) make reliance on a single technique undesirable. An algorithmic approach using 67Ga or 111In-WBC scintigraphy, CT, and US provides a logical and clinically practical approach to complicated abdominal infection. By recognizing differences in clinical presentation and by appreciating the diagnostic strengths and weaknesses of nuclear medicine, CT, and US, the algorithm provides a reliable and direct route to accurate diagnosis while minimizing unnecessary examinations.« less
  • Primary aortic neoplasms are rare. Aortic sarcoma arising after endovascular aneurysm repair (EVAR) is a scarce subset of primary aortic malignancies, reports of which are infrequent in the published literature. The diagnosis of aortic sarcoma is challenging due to its non-specific clinical presentation, and the prognosis is poor due to delayed diagnosis, rapid proliferation, and propensity for metastasis. Post-EVAR, aortic sarcomas may mimic other more common aortic processes on surveillance imaging. Radiologists are rarely knowledgeable about this rare entity for which multimodality imaging and awareness are invaluable in early diagnosis. A series of three pathologically confirmed cases are presented tomore » display the multimodality imaging features and clinical presentations of aortic sarcoma arising after EVAR.« less