skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Spectrometer for cluster ion beam induced luminescence

Abstract

A spectrometer to detect the ultra-weak luminescence originated by the collision of cluster ions on the surfaces of solid materials was constructed. This spectrometer consists of 11 photomultipliers with band-pass interference filters that can detect the luminescence within the wavelength ranging from 300 to 700 nm and of a photomultiplier without filter. The calibration of the detection system was performed using the photons emitted from a strontium aluminate fluorescent tape and from a high temperature tungsten filament. Preliminary measurements show the ability of this spectrometer to detect the cluster ion beam induced luminescence.

Authors:
; ; ;  [1];  [2];  [3]
  1. Photonics and Electronics Science and Engineering Center, Kyoto University, Kyoto 615-8510 (Japan)
  2. Department of Physics and Astronomy, Catania University, Catania 95123 (Italy)
  3. (Italy)
Publication Date:
OSTI Identifier:
22392348
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 86; Journal Issue: 2; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ALUMINATES; CALIBRATION; FILAMENTS; FILTERS; FLUORESCENCE; INTERFERENCE; ION COLLISIONS; ION PAIRS; PHOTOMULTIPLIERS; SPECTROMETERS

Citation Formats

Ryuto, H., E-mail: ryuto@kuee.kyoto-u.ac.jp, Sakata, A., Takeuchi, M., Takaoka, G. H., Musumeci, F., and INFN Laboratori Nazionali del Sud, Catania 95123. Spectrometer for cluster ion beam induced luminescence. United States: N. p., 2015. Web. doi:10.1063/1.4907540.
Ryuto, H., E-mail: ryuto@kuee.kyoto-u.ac.jp, Sakata, A., Takeuchi, M., Takaoka, G. H., Musumeci, F., & INFN Laboratori Nazionali del Sud, Catania 95123. Spectrometer for cluster ion beam induced luminescence. United States. doi:10.1063/1.4907540.
Ryuto, H., E-mail: ryuto@kuee.kyoto-u.ac.jp, Sakata, A., Takeuchi, M., Takaoka, G. H., Musumeci, F., and INFN Laboratori Nazionali del Sud, Catania 95123. Sun . "Spectrometer for cluster ion beam induced luminescence". United States. doi:10.1063/1.4907540.
@article{osti_22392348,
title = {Spectrometer for cluster ion beam induced luminescence},
author = {Ryuto, H., E-mail: ryuto@kuee.kyoto-u.ac.jp and Sakata, A. and Takeuchi, M. and Takaoka, G. H. and Musumeci, F. and INFN Laboratori Nazionali del Sud, Catania 95123},
abstractNote = {A spectrometer to detect the ultra-weak luminescence originated by the collision of cluster ions on the surfaces of solid materials was constructed. This spectrometer consists of 11 photomultipliers with band-pass interference filters that can detect the luminescence within the wavelength ranging from 300 to 700 nm and of a photomultiplier without filter. The calibration of the detection system was performed using the photons emitted from a strontium aluminate fluorescent tape and from a high temperature tungsten filament. Preliminary measurements show the ability of this spectrometer to detect the cluster ion beam induced luminescence.},
doi = {10.1063/1.4907540},
journal = {Review of Scientific Instruments},
number = 2,
volume = 86,
place = {United States},
year = {Sun Feb 15 00:00:00 EST 2015},
month = {Sun Feb 15 00:00:00 EST 2015}
}