skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Note: Effect of hot liner in producing {sup 40,48}Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source

Abstract

In order to produce a high-intensity and stable {sup 48}Ca beam from the RIKEN 18-GHz electron cyclotron resonance ion source, we have begun testing the production of a calcium beam using a micro-oven. To minimize the consumption rate of the material ({sup 48}Ca), we introduced the “hot liner” method and investigated the effect of the liner on the material consumption rate. The micro-oven was first used to produce the {sup 48}Ca beam for experiments in the RIKEN radioisotope beam factory, and a stable beam could be supplied for a long time with low consumption rate.

Authors:
; ; ;  [1]
  1. Nishina Center for Accelerator Based Science, RIKEN, Wako, Saitama 351-0198 (Japan)
Publication Date:
OSTI Identifier:
22392342
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 86; Journal Issue: 1; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
07 ISOTOPES AND RADIATION SOURCES; 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; CALCIUM 40 BEAMS; CALCIUM 48 BEAMS; ECR ION SOURCES; GHZ RANGE; ISOTOPE PRODUCTION; LINERS; RADIOISOTOPES

Citation Formats

Ozeki, K., E-mail: k-ozeki@riken.jp, Higurashi, Y., Kidera, M., and Nakagawa, T. Note: Effect of hot liner in producing {sup 40,48}Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source. United States: N. p., 2015. Web. doi:10.1063/1.4906595.
Ozeki, K., E-mail: k-ozeki@riken.jp, Higurashi, Y., Kidera, M., & Nakagawa, T. Note: Effect of hot liner in producing {sup 40,48}Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source. United States. doi:10.1063/1.4906595.
Ozeki, K., E-mail: k-ozeki@riken.jp, Higurashi, Y., Kidera, M., and Nakagawa, T. Thu . "Note: Effect of hot liner in producing {sup 40,48}Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source". United States. doi:10.1063/1.4906595.
@article{osti_22392342,
title = {Note: Effect of hot liner in producing {sup 40,48}Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source},
author = {Ozeki, K., E-mail: k-ozeki@riken.jp and Higurashi, Y. and Kidera, M. and Nakagawa, T.},
abstractNote = {In order to produce a high-intensity and stable {sup 48}Ca beam from the RIKEN 18-GHz electron cyclotron resonance ion source, we have begun testing the production of a calcium beam using a micro-oven. To minimize the consumption rate of the material ({sup 48}Ca), we introduced the “hot liner” method and investigated the effect of the liner on the material consumption rate. The micro-oven was first used to produce the {sup 48}Ca beam for experiments in the RIKEN radioisotope beam factory, and a stable beam could be supplied for a long time with low consumption rate.},
doi = {10.1063/1.4906595},
journal = {Review of Scientific Instruments},
number = 1,
volume = 86,
place = {United States},
year = {Thu Jan 15 00:00:00 EST 2015},
month = {Thu Jan 15 00:00:00 EST 2015}
}