skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Phase contrast portal imaging using synchrotron radiation

Abstract

Microbeam radiation therapy is an experimental form of radiation treatment with great potential to improve the treatment of many types of cancer. We applied a synchrotron radiation phase contrast technique to portal imaging to improve targeting accuracy for microbeam radiation therapy in experiments using small animals. An X-ray imaging detector was installed 6.0 m downstream from an object to produce a high-contrast edge enhancement effect in propagation-based phase contrast imaging. Images of a mouse head sample were obtained using therapeutic white synchrotron radiation with a mean beam energy of 130 keV. Compared to conventional portal images, remarkably clear images of bones surrounding the cerebrum were acquired in an air environment for positioning brain lesions with respect to the skull structure without confusion with overlapping surface structures.

Authors:
 [1];  [2]
  1. Japan Synchrotron Radiation Research Institute, SPring-8, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan)
  2. Kobe University Graduate School of Medicine, Kusunoki-cho, Chuo-ku, Kobe-shi, Hyogo 650-0017 (Japan)
Publication Date:
OSTI Identifier:
22308680
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 85; Journal Issue: 7; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 62 RADIOLOGY AND NUCLEAR MEDICINE; CEREBRUM; IMAGES; KEV RANGE; MICE; NEOPLASMS; POSITIONING; RADIOTHERAPY; SKULL; SYNCHROTRON RADIATION; X-RAY RADIOGRAPHY

Citation Formats

Umetani, K., E-mail: umetani@spring8.or.jp, and Kondoh, T. Phase contrast portal imaging using synchrotron radiation. United States: N. p., 2014. Web. doi:10.1063/1.4885755.
Umetani, K., E-mail: umetani@spring8.or.jp, & Kondoh, T. Phase contrast portal imaging using synchrotron radiation. United States. doi:10.1063/1.4885755.
Umetani, K., E-mail: umetani@spring8.or.jp, and Kondoh, T. Tue . "Phase contrast portal imaging using synchrotron radiation". United States. doi:10.1063/1.4885755.
@article{osti_22308680,
title = {Phase contrast portal imaging using synchrotron radiation},
author = {Umetani, K., E-mail: umetani@spring8.or.jp and Kondoh, T.},
abstractNote = {Microbeam radiation therapy is an experimental form of radiation treatment with great potential to improve the treatment of many types of cancer. We applied a synchrotron radiation phase contrast technique to portal imaging to improve targeting accuracy for microbeam radiation therapy in experiments using small animals. An X-ray imaging detector was installed 6.0 m downstream from an object to produce a high-contrast edge enhancement effect in propagation-based phase contrast imaging. Images of a mouse head sample were obtained using therapeutic white synchrotron radiation with a mean beam energy of 130 keV. Compared to conventional portal images, remarkably clear images of bones surrounding the cerebrum were acquired in an air environment for positioning brain lesions with respect to the skull structure without confusion with overlapping surface structures.},
doi = {10.1063/1.4885755},
journal = {Review of Scientific Instruments},
number = 7,
volume = 85,
place = {United States},
year = {Tue Jul 15 00:00:00 EDT 2014},
month = {Tue Jul 15 00:00:00 EDT 2014}
}