Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)
- Department of Surgery (Neurosurgical Division), Memorial Sloan-Kettering Cancer Center, New York, New York (United States)
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)
Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher's exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade {>=}3 acute or late toxicity was 6.8% (14 patients). Fisher's exact test resulted in significant median splits for grade {>=}3 toxicity at V12 = 3.78 cm{sup 3} (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm{sup 3} (RR 13, P=.0013), V20 = 0.11 cm{sup 3} (RR 6, P=0.01), and V22 = 0.0 cm{sup 3} (RR 13, P=.0013). The median split for D2.5 cm{sup 3} (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm{sup 3}. One hundred percent (n = 7) of grade {>=}4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade {>=}3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are associated with development of grade {>=}4 toxicity.
- OSTI ID:
- 22149418
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Vol. 83, Issue 5; Other Information: Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
Local Control and Toxicity in a Large Cohort of Central Lung Tumors Treated With Stereotactic Body Radiation Therapy
Risk factors for acute esophagitis in non-small-cell lung cancer patients treated with concurrent chemotherapy and three-dimensional conformal radiotherapy