Title: Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture

Abstract

The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient's clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of the stent-graft creating a 'false channel' that compressed the 'true lumen' and induced 'pseudocoarctation' syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.

Authors:
; ;  [1];  [2]; ;  [1];  [3];  [1]
  1. University Hospital of Nantes, Institut du Thorax (France)
  2. University Hospital of Nantes, Department of Pathology (France)
  3. University Hospital of Toulouse, Department of Radiology (France)
Publication Date:
OSTI Identifier:
22113669
Resource Type:
Journal Article
Resource Relation:
Journal Name: Cardiovascular and Interventional Radiology; Journal Volume: 36; Journal Issue: 3; Other Information: Copyright (c) 2013 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Article Copyright (c) 2012 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; ACCIDENTS; BIOMEDICAL RADIOGRAPHY; GRAFTS; IMPLANTS; NMR IMAGING; PATIENTS; SURGERY

Citation Formats

Letocart, Vincent, E-mail: vincent.letocart@chu-nantes.fr, Fau, Georges, E-mail: georges.fau@chu-nantes.fr, Tirouvanziam, Ashok, E-mail: ashok.tirouvanziam@chu-nantes.fr, Toquet, Claire, E-mail: claire.toquet@chu-nantes.fr, Al Habash, Oussama, E-mail: oussama.alhabash@chu-nantes.fr, Guerin, Patrice, E-mail: patrice.guerin@chu-nantes.fr, Rousseau, Herve, E-mail: rousseau.h@chu-toulouse.fr, and Crochet, Dominique, E-mail: dominique.crochet@chu-nantes.fr. Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture. United States: N. p., 2013. Web. doi:10.1007/S00270-012-0436-7.
Letocart, Vincent, E-mail: vincent.letocart@chu-nantes.fr, Fau, Georges, E-mail: georges.fau@chu-nantes.fr, Tirouvanziam, Ashok, E-mail: ashok.tirouvanziam@chu-nantes.fr, Toquet, Claire, E-mail: claire.toquet@chu-nantes.fr, Al Habash, Oussama, E-mail: oussama.alhabash@chu-nantes.fr, Guerin, Patrice, E-mail: patrice.guerin@chu-nantes.fr, Rousseau, Herve, E-mail: rousseau.h@chu-toulouse.fr, & Crochet, Dominique, E-mail: dominique.crochet@chu-nantes.fr. Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture. United States. doi:10.1007/S00270-012-0436-7.
Letocart, Vincent, E-mail: vincent.letocart@chu-nantes.fr, Fau, Georges, E-mail: georges.fau@chu-nantes.fr, Tirouvanziam, Ashok, E-mail: ashok.tirouvanziam@chu-nantes.fr, Toquet, Claire, E-mail: claire.toquet@chu-nantes.fr, Al Habash, Oussama, E-mail: oussama.alhabash@chu-nantes.fr, Guerin, Patrice, E-mail: patrice.guerin@chu-nantes.fr, Rousseau, Herve, E-mail: rousseau.h@chu-toulouse.fr, and Crochet, Dominique, E-mail: dominique.crochet@chu-nantes.fr. Sat . "Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture". United States. doi:10.1007/S00270-012-0436-7.
@article{osti_22113669,
title = {Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture},
author = {Letocart, Vincent, E-mail: vincent.letocart@chu-nantes.fr and Fau, Georges, E-mail: georges.fau@chu-nantes.fr and Tirouvanziam, Ashok, E-mail: ashok.tirouvanziam@chu-nantes.fr and Toquet, Claire, E-mail: claire.toquet@chu-nantes.fr and Al Habash, Oussama, E-mail: oussama.alhabash@chu-nantes.fr and Guerin, Patrice, E-mail: patrice.guerin@chu-nantes.fr and Rousseau, Herve, E-mail: rousseau.h@chu-toulouse.fr and Crochet, Dominique, E-mail: dominique.crochet@chu-nantes.fr},
abstractNote = {The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient's clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of the stent-graft creating a 'false channel' that compressed the 'true lumen' and induced 'pseudocoarctation' syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.},
doi = {10.1007/S00270-012-0436-7},
journal = {Cardiovascular and Interventional Radiology},
number = 3,
volume = 36,
place = {United States},
year = {Sat Jun 15 00:00:00 EDT 2013},
month = {Sat Jun 15 00:00:00 EDT 2013}
}