skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata

Abstract

Variable Energy Cyclotron Centre has commissioned a K-500 superconducting cyclotron for various types of nuclear physics experiments. The 3-phase radio-frequency system of superconducting cyclotron has been developed in the frequency range 9-27 MHz with amplitude and phase stability of 100 ppm and {+-}0.2{sup 0}, respectively. The analysis of the RF cavity has been carried out using 3D Computer Simulation Technology (CST) Microwave Studio code and various RF parameters and accelerating voltages ('Dee' voltage) are calculated from simulation. During the RF system commissioning, measurement of different RF parameters has been done and absolute Dee voltage has been calibrated using a CdTe X-ray detector along with its accessories and known X-ray source. The present paper discusses about the measured data and the simulation result.

Authors:
; ; ; ;  [1]
  1. Variable Energy Cyclotron Centre, Kolkata (India)
Publication Date:
OSTI Identifier:
22105402
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 84; Journal Issue: 2; Other Information: (c) 2013 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 43 PARTICLE ACCELERATORS; CADMIUM TELLURIDES; CALIBRATION; COMPUTERIZED SIMULATION; ELECTRIC POTENTIAL; NUCLEAR PHYSICS; PHASE STABILITY; RADIOWAVE RADIATION; RF SYSTEMS; SUPERCONDUCTING CYCLOTRONS; VARIABLE ENERGY CYCLOTRONS; X RADIATION

Citation Formats

Som, Sumit, Seth, Sudeshna, Mandal, Aditya, Paul, Saikat, and Duttagupta, Anjan. Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata. United States: N. p., 2013. Web. doi:10.1063/1.4789784.
Som, Sumit, Seth, Sudeshna, Mandal, Aditya, Paul, Saikat, & Duttagupta, Anjan. Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata. United States. doi:10.1063/1.4789784.
Som, Sumit, Seth, Sudeshna, Mandal, Aditya, Paul, Saikat, and Duttagupta, Anjan. Fri . "Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata". United States. doi:10.1063/1.4789784.
@article{osti_22105402,
title = {Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata},
author = {Som, Sumit and Seth, Sudeshna and Mandal, Aditya and Paul, Saikat and Duttagupta, Anjan},
abstractNote = {Variable Energy Cyclotron Centre has commissioned a K-500 superconducting cyclotron for various types of nuclear physics experiments. The 3-phase radio-frequency system of superconducting cyclotron has been developed in the frequency range 9-27 MHz with amplitude and phase stability of 100 ppm and {+-}0.2{sup 0}, respectively. The analysis of the RF cavity has been carried out using 3D Computer Simulation Technology (CST) Microwave Studio code and various RF parameters and accelerating voltages ('Dee' voltage) are calculated from simulation. During the RF system commissioning, measurement of different RF parameters has been done and absolute Dee voltage has been calibrated using a CdTe X-ray detector along with its accessories and known X-ray source. The present paper discusses about the measured data and the simulation result.},