skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Investigation of the Relationship Between Gross Tumor Volume Location and Pneumonitis Rates Using a Large Clinical Database of Non-Small-Cell Lung Cancer Patients

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2];  [3];  [1]
  1. Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States)
  2. Department of Bioinformatics and Computational Biology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)
  3. Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

Purpose: Studies have suggested that function may vary throughout the lung, and that patients who have tumors located in the base of the lung are more susceptible to radiation pneumonitis. The purpose of our study was to investigate the relationship between gross tumor volume (GTV) location and pneumonitis rates using a large clinical database of 547 patients with non-small-cell lung cancer. Methods and Materials: The GTV centroids of all patients were mapped onto one common coordinate system, in which the boundaries of the coordinate system were defined by the extreme points of each individual patient lung. The data were qualitatively analyzed by graphing all centroids and displaying the data according to the presence of severe pneumonitis, tumor stage, and smoking status. The centroids were grouped according to superior-inferior segments, and the pneumonitis rates were analyzed. In addition, we incorporated the GTV centroid information into a Lyman-Kutcher-Burman normal tissue complication probability model and tested whether adding spatial information significantly improved the fit of the model. Results: Of the 547 patients analyzed, 111 (20.3%) experienced severe radiation pneumonitis. The pneumonitis incidence rates were 16%, 23%, and 21% for the superior, middle, and inferior thirds of the lung, respectively. Qualitatively, the GTV centroids of nonsmokers were notably absent from the superior portion of the lung. In addition, the GTV centroids of patients who had Stage III and IV clinical staging were concentrated toward the medial edge of the lung. The comparison between the GTV centroid model and the conventional dose-volume model did not yield a statistically significant difference in model fit. Conclusions: Lower pneumonitis rates were noted for the superior portion of the lung; however the differences were not statistically significant. For our patient cohort, incorporating GTV centroid information did not lead to a statistically significant improvement in the fit of the pneumonitis model.

OSTI ID:
22056209
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 82, Issue 5; Other Information: Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

A Novel Method to Incorporate the Spatial Location of the Lung Dose Distribution into Predictive Radiation Pneumonitis Modeling
Journal Article · Thu Mar 15 00:00:00 EDT 2012 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22056209

Lung Size and the Risk of Radiation Pneumonitis
Journal Article · Mon Feb 01 00:00:00 EST 2016 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22056209

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 03: The Potential Benefit Of Esophageal Sparing During Palliative Radiotherapy For Lung Cancer
Journal Article · Mon Aug 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:22056209