skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Improvement of voltage holding capability in the 500 keV negative ion source for JT-60SA

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3279399· OSTI ID:22053837
; ; ; ; ; ; ; ; ; ; ;  [1];  [2]
  1. Japan Atomic Energy Agency, Naka, Ibaraki 311-0193 (Japan)
  2. Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

Voltage holding capability of JT-60 negative ion source that has a large electrostatic negative ion accelerator with 45 cmx1.1 m acceleration grids was experimentally examined and improved to realize 500 keV, 22 A, and 100 s D{sup -} ion beams for JT-60 Super Advanced. The gap lengths in the acceleration stages were extended to reduce electric fields in a gap between the large grids and at the corner of the support flanges from the original 4-5 to 3-4 kV/mm. As a result, the voltage holding capability without beam acceleration has been successfully improved from 400 to 500 kV. The pulse duration to hold 500 kV reached 40 s of the power supply limitation.

OSTI ID:
22053837
Journal Information:
Review of Scientific Instruments, Vol. 81, Issue 2; Conference: ICIS 2009: 13. international conference on ion sources, Gatlinburg, TN (United States), 20-25 Sep 2009; Other Information: (c) 2010 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English