skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Shot-noise-limited control-loop noise in an interferometer with multiple degrees of freedom

Journal Article · · Applied Optics
DOI:https://doi.org/10.1364/AO.49.004335· OSTI ID:22036518

Precise measurements, such as those made with interferometric gravitational-wave detectors, require the measurement device to be properly controlled so that the sensitivity can be as high as possible. Mirrors in the interferometer are to be located at specific operation points to isolate laser noise and to accumulate the signal in resonant cavities. On the other hand, rigid control of an auxiliary degree of freedom may result in imposing sensing noise of the control on the target object as excess force noise. Evaluation of this so-called loop noise is important in order to design a decent control scheme of the measurement device. In this paper, we show the method to calculate the level of loop noise, which has been recently implemented in simulation tools that are broadly used for designing gravitational-wave detectors.

OSTI ID:
22036518
Journal Information:
Applied Optics, Vol. 49, Issue 23; Other Information: (c) 2010 Optical Society of America; Country of input: International Atomic Energy Agency (IAEA); ISSN 0003-6935
Country of Publication:
United States
Language:
English