skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood-Brain Barrier Disruption

Abstract

Purpose: A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood-brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Methods: Nineteen patients-5 acute-phase and 14 scheduled-underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors were examined. Results: CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Conclusions: Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemicmore » intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.« less

Authors:
;  [1];  [2];  [1];  [3]
  1. Mazda Hospital, Department of Neurosurgery (Japan)
  2. Shimane Prefectural Central Hospital, Department of Neurosurgery (Japan)
  3. Hiroshima University Graduate School of Biomedical Sciences, Department of Neurosurgery (Japan)
Publication Date:
OSTI Identifier:
21608585
Resource Type:
Journal Article
Resource Relation:
Journal Name: Cardiovascular and Interventional Radiology; Journal Volume: 34; Journal Issue: 5; Other Information: DOI: 10.1007/s00270-010-0035-4; Copyright (c) 2011 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; BLOOD-BRAIN BARRIER; CALCIUM SULFIDES; CAROTID ARTERIES; CEREBROSPINAL FLUID; CESIUM FLUORIDES; FLUIDS; HAZARDS; IMAGES; INJURIES; INSTABILITY; PATIENTS; SAFETY; SYMPTOMS; ALKALI METAL COMPOUNDS; ALKALINE EARTH METAL COMPOUNDS; ARTERIES; BIOLOGICAL MATERIALS; BLOOD VESSELS; BODY; BODY FLUIDS; CALCIUM COMPOUNDS; CARDIOVASCULAR SYSTEM; CESIUM COMPOUNDS; CESIUM HALIDES; CHALCOGENIDES; DISEASES; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; MATERIALS; ORGANS; SULFIDES; SULFUR COMPOUNDS

Citation Formats

Ogami, Ryo, E-mail: ogami.r@mazda.co.jp, Nakahara, Toshinori, Hamasaki, Osamu, Araki, Hayato, and Kurisu, Kaoru. Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood-Brain Barrier Disruption. United States: N. p., 2011. Web. doi:10.1007/S00270-010-0035-4.
Ogami, Ryo, E-mail: ogami.r@mazda.co.jp, Nakahara, Toshinori, Hamasaki, Osamu, Araki, Hayato, & Kurisu, Kaoru. Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood-Brain Barrier Disruption. United States. doi:10.1007/S00270-010-0035-4.
Ogami, Ryo, E-mail: ogami.r@mazda.co.jp, Nakahara, Toshinori, Hamasaki, Osamu, Araki, Hayato, and Kurisu, Kaoru. 2011. "Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood-Brain Barrier Disruption". United States. doi:10.1007/S00270-010-0035-4.
@article{osti_21608585,
title = {Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood-Brain Barrier Disruption},
author = {Ogami, Ryo, E-mail: ogami.r@mazda.co.jp and Nakahara, Toshinori and Hamasaki, Osamu and Araki, Hayato and Kurisu, Kaoru},
abstractNote = {Purpose: A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood-brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Methods: Nineteen patients-5 acute-phase and 14 scheduled-underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors were examined. Results: CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Conclusions: Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.},
doi = {10.1007/S00270-010-0035-4},
journal = {Cardiovascular and Interventional Radiology},
number = 5,
volume = 34,
place = {United States},
year = 2011,
month =
}
  • AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateralmore » ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm{sup 3} (interquartile range 0.065–0.146 cm{sup 3}). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.« less
  • Purpose. To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. Methods. Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 {mu}m. All stents were deployed across the bifurcation and the external carotidmore » artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. Results. The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. Conclusions. Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow behavior. Depending on the stent design the flow alterations are located in different regions. All the stents tested were suitable for the carotid bifurcation. The MembraX prototype has shown promising hemodynamic properties ex vivo.« less
  • To evaluate fast fluid-attenuated inversion-recovery (FLAIR) technique for imaging brain abnormalities. A fast FLAIR sequence was developed that provided 36 5-mm contiguous sections in 5 minutes 8 seconds. Resulting images were compared with dual-echo T2-weighted spin-echo images of 41 consecutive patients with brain abnormalities. Contrast and contrast-to-noise ratios (C/Ns) (for contrast between the lesion and background and between the lesion and cerebrospinal fluid) for fast FLAIR exceeded the corresponding values for T2-weighted spin-echo images for all but the second-echo lesion-to-background C/N. Fast FLAIR provided equivalent or greater overall lesion conspicuity and enabled greater lesion detection in 98% and 100%, respectively,more » of the evaluations. Fast FLAIR images more often had image artifact, but this did not interfere with image interpretation in a significantly (P {<=} .05) greater number of evaluations. Fast FLAIR provides images that are superior to proton-density- and T2-weighted images for many image quality criteria. 29 refs., 7 figs., 4 tabs.« less
  • The assessment of the intracranial hemodynamic consequences of obstructive lesions of the carotid artery by measuring resting rCBF is inadequate because cerebral blood flow may remain constant in spite of significant drops in the intraluminal pressure due to autoregulation. Moreover, flow may be permanently decreased following cerebral infarction, even if the arterial anatomical conditions have resumed their normal state because of the decreased metabolic demand of an infarcted area. Measurement of the regional cerebral blood volume (rCBV) helps with the hemodynamic assessment of these conditions, since there is a linear and inverse relationship between intraarterial pressure and intracranial blood volume.more » In 24 patients exhibiting various carotid and ischemic brain lesions we studied both rCBF and rCBV. The latter is a comparative measure between hemispheres obtained by single photon emission tomography after autotransfusion of 99mTechnetium labeled erythrocytes. There was no correlation between rCBF and clinical status, CT scan or arterial lesions. There was no correlation between rCBV and clinical status or CT scan. There was, however, an interesting correlation between rCBV and the severity of the arterial lesion. The rCBV was symmetrical in all patients with normal or moderately stenotic carotid arteries before and after operation. In some patients with severe unilateral stenosis or occlusion, there was a significant relative increase of rCBV in the hemisphere downstream from the lesion, which disappeared after surgery (endarterectomy or extra-intracranial bypass). In some patients with severe and bilateral carotid lesions, we noted an asymmetry in rCBV that disappeared after a unilateral operation. Other patients with similar lesions develop asymmetry only after an operation that resulted in a relative increase in rCBV in the hemisphere supplied by the non-operated artery.« less