Title: Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

Abstract

We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

Authors:
; ; ;  [1]
  1. Nara Medical University, Department of Radiology (Japan)
Publication Date:
OSTI Identifier:
21450345
Resource Type:
Journal Article
Resource Relation:
Journal Name: Cardiovascular and Interventional Radiology; Journal Volume: 31; Journal Issue: 5; Other Information: DOI: 10.1007/s00270-008-9301-0; Copyright (c) 2008 Springer Science+Business Media, LLC
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; ARTERIES; FRACTURES; VASCULAR DISEASES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DISEASES; FAILURES; ORGANS

Citation Formats

Higashiura, Wataru, E-mail: wataruhigashiura@hotmail.com, Sakaguchi, Shoji, Morimoto, Kengo, and Kichikawa, Kimihiko. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment. United States: N. p., 2008. Web. doi:10.1007/S00270-008-9301-0.
Higashiura, Wataru, E-mail: wataruhigashiura@hotmail.com, Sakaguchi, Shoji, Morimoto, Kengo, & Kichikawa, Kimihiko. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment. United States. doi:10.1007/S00270-008-9301-0.
Higashiura, Wataru, E-mail: wataruhigashiura@hotmail.com, Sakaguchi, Shoji, Morimoto, Kengo, and Kichikawa, Kimihiko. 2008. "Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment". United States. doi:10.1007/S00270-008-9301-0.
@article{osti_21450345,
title = {Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment},
author = {Higashiura, Wataru, E-mail: wataruhigashiura@hotmail.com and Sakaguchi, Shoji and Morimoto, Kengo and Kichikawa, Kimihiko},
abstractNote = {We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.},
doi = {10.1007/S00270-008-9301-0},
journal = {Cardiovascular and Interventional Radiology},
number = 5,
volume = 31,
place = {United States},
year = 2008,
month = 9
}
  • Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent. Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients' chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed. Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery,more » and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively. Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.« less
  • We report the case of a patient who developed an asymptomatic pseudoaneurysm in the left external iliac artery after transplant nephrectomy. The pseudoaneurysm most probably arose as a suture aneurysm from the external iliac artery after removal of the graft renal artery. Obviously we can not exclude the possibility it was a true aneurysm, although this seems much less likely. The pseudoaneurysm was detected during a routine CT scan and was treated interventionally with a stent-graft. One month later the asymptomatic patient underwent a vascular ultrasound examination including color Doppler, power Doppler, and B-flow as a routine control. An endoleakmore » with collapse of the stent-graft was diagnosed. There was no evidence of stent infection. At a reintervention, the pseudoaneurysm was successfully treated using two uncovered Palmaz stents at the proximal and distal edge of the stent graft. Peri- and post-interventional ultrasound and CT angiography confirmed the exclusion of the aneurysm without an endoleak.« less
  • Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkagemore » at week 1, 3, 6, and 12 months and once every year thereafter. Non-contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47-2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.« less
  • Isolated spontaneous dissection of the common iliac artery (CIA) is a rare entity. Two patients with this condition were successfully treated by percutaneous stent placement. We emphasize the feasibility of nonsurgical management by percutaneous stent placement for isolated spontaneous dissection of the CIA.
  • The purpose of this study was to evaluate the usefulness of a bifurcated stent-graft with a wide iliac limb end (WILE) in the treatment of abdominal aortic aneurysm (AAA) with a dilated common iliac artery (CIA) to avoid occlusion of the internaliliac artery (IIA). The WILE, covered with an expanded polytetrafluoroethylene graft which was constructed of large diameter stents according to the individual CIA diameter, was connected to a two-piece bifurcated stent-graft covering a polyester graft. The WILE was placed in eight dilated CIAs of six patients. All but one WILE fitted the dilated CIA well. One did not fit,more » and coil embolization of the leak was needed. All eight IIA derived from the dilated CIA avoided occlusion. Perigraft leak due to other causes was identified in another two patients. Limb kinking was observed in two patients. Our stent is useful in the treatment of AAA with dilated CIA to avoid occlusion of the IIA, and may extend the indication of endoluminal repair of AAA.« less