Chirping the probe pulse in a coherent transients experiment
Abstract
Coherent transients occur when a chirped pump pulse excites a two-level transition. They have been observed with an ultrashort probe pulse. Several studies have been dedicated to using various pump shapes. In this study, the roles of the pump and the probe pulses are reversed. With a Fourier-transform-limited pump pulse followed by a chirped-probe pulse, similar effects can be observed. Finally, the case of two pulses with opposite chirps is considered.
- Authors:
-
- CNRS-Universite de Toulouse, UPS, Laboratoire Collisions, Agregats Reactivite, IRSAMC, F-31062 Toulouse (France)
- Publication Date:
- OSTI Identifier:
- 21408268
- Resource Type:
- Journal Article
- Journal Name:
- Physical Review. A
- Additional Journal Information:
- Journal Volume: 81; Journal Issue: 2; Other Information: DOI: 10.1103/PhysRevA.81.023415; (c) 2010 The American Physical Society; Journal ID: ISSN 1050-2947
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 74 ATOMIC AND MOLECULAR PHYSICS; FOURIER TRANSFORMATION; PROBES; PULSES; PUMPS; SHAPE; TRANSIENTS; EQUIPMENT; INTEGRAL TRANSFORMATIONS; TRANSFORMATIONS
Citation Formats
Weber, Sebastien, Girard, Bertrand, and Chatel, Beatrice. Chirping the probe pulse in a coherent transients experiment. United States: N. p., 2010.
Web. doi:10.1103/PHYSREVA.81.023415.
Weber, Sebastien, Girard, Bertrand, & Chatel, Beatrice. Chirping the probe pulse in a coherent transients experiment. United States. https://doi.org/10.1103/PHYSREVA.81.023415
Weber, Sebastien, Girard, Bertrand, and Chatel, Beatrice. 2010.
"Chirping the probe pulse in a coherent transients experiment". United States. https://doi.org/10.1103/PHYSREVA.81.023415.
@article{osti_21408268,
title = {Chirping the probe pulse in a coherent transients experiment},
author = {Weber, Sebastien and Girard, Bertrand and Chatel, Beatrice},
abstractNote = {Coherent transients occur when a chirped pump pulse excites a two-level transition. They have been observed with an ultrashort probe pulse. Several studies have been dedicated to using various pump shapes. In this study, the roles of the pump and the probe pulses are reversed. With a Fourier-transform-limited pump pulse followed by a chirped-probe pulse, similar effects can be observed. Finally, the case of two pulses with opposite chirps is considered.},
doi = {10.1103/PHYSREVA.81.023415},
url = {https://www.osti.gov/biblio/21408268},
journal = {Physical Review. A},
issn = {1050-2947},
number = 2,
volume = 81,
place = {United States},
year = {Mon Feb 15 00:00:00 EST 2010},
month = {Mon Feb 15 00:00:00 EST 2010}
}
Other availability
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.