Title: Improvement of the noise figure of the CEBAF switched electrode electronics BPM system

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.57005· OSTI ID:21202371
 [1]
  1. Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, Virginia 23606 (United States)

The Continuous Electron Beam Accelerator Facility (CEBAF) is a high-intensity continuous wave electron accelerator for nuclear physics located at Thomas Jefferson National Accelerator Facility. A beam energy of 4 GeV is achieved by recirculating the electron beam five times through two anti-parallel 400 MeV linacs. In the linacs, where there is recirculated beam, the BPM specifications must be met for beam intensities between 1 and 100 {mu}A. In the transport lines the BPM specifications must be met for beam intensities between 100 nA and 200 {mu}A. To avoid a complete redesign of the existing electronics, we investigated ways to improve the noise figure of the linac BPM switched-electrode electronics (SEE) so that they could be used in the transport lines. We found that the out-of-band noise contributed significantly to the overall system noise figure. This paper will focus on the source of the excessive out-of-band noise and how it was reduced. The development, commissioning and operational results of this low noise variant of the linac style SEE BPMs as well as techniques for determining the noise figure of the rf chain will also be presented.

OSTI ID:
21202371
Journal Information:
AIP Conference Proceedings, Vol. 451, Issue 1; Conference: 8. beam instrumentation workshop, Stanford, CA (United States), 4-7 May 1998; Other Information: DOI: 10.1063/1.57005; (c) 1998 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Improvement of the noise figure of the CEBAF switched electrode electronics BPM system
Journal Article · Tue Dec 01 00:00:00 EST 1998 · AIP Conference Proceedings · OSTI ID:21202371

Improvement of the noise figure of the CEBAF switched electrode electronics BPM system
Conference · Fri May 01 00:00:00 EDT 1998 · OSTI ID:21202371

Electronics systems for beam position monitors at CEBAF
Conference · Sat Jun 01 00:00:00 EDT 1991 · AIP Conference Proceedings (American Institute of Physics); (United States) · OSTI ID:21202371